VVB3
Mechanical & physical measurement

Humidity & air temperature
The HC100 series is an advanced portable humidity validator for the verification and calibration of humidity sensors. It generates defined humidity and temperature conditions in a small chamber and compares the readings of the probes under test with its built-in reference, so that several probes can be checked in one run on site or in the workshop.
The unit generates relative humidity from 5 to 95 %RH and temperatures from +10 to +50 °C. The generated humidity is held with a stability of 0.1 %RH, and the response time for humidity and temperature changes is less than five minutes. Accuracy is ±0.8 %RH. The reference measurement uses a capacitive humidity sensor and a Pt100 RTD to IEC 751, 1/3 Class B, with a measuring range of 0 to 100 %RH and −50 to 100 °C.
The chamber has a volume of 1.05 litres and up to eight probe ports with blind-stop M30 × 1 mounts, so that up to seven probes can be validated at the same time. An intuitive user interface automates the validation procedure, allowing complete hands-off probe verification once the probes are inserted. Results and set-points are shown on a 4.3-digit LCD, and the device supports Modbus communication and remote API capabilities for integration into calibration software.
The HC100 is powered from 24 V DC, and an optional battery pack allows operation in the field without mains supply. The housing is made of acetal; the unit measures 300 × 250 × 100 mm and weighs 7.055 lb. It is intended for ambient temperatures from 5 to 40 °C. A hard carry case is available for transport.
Three versions are listed: HC100A, HC100A1 and HC100A8. Calibration certificates can be supplied with UKAS accreditation or as SCS certificates, and traceable calibrations of the validator itself can be performed using chilled mirror reference hygrometers.
Typical uses are verification and calibration of humidity sensors and automated validation procedures for hands-off probe checks. Please state the number and type of probes to be validated, the probe diameter and whether battery operation is required, so that we can confirm the right version and accessories.
HC100A, HC100A1, HC100A8
Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.