The HH920B-IS series consists of intrinsically safe handheld thermocouple meters for temperature measurement in hazardous locations. Model 921B has a single input and model 922B two inputs, which also allows differential measurement (T1−T2).
The meters work with standard thermocouples of types J, K, T, E, N, R, B and S, connected through miniature thermocouple connectors. The readings are updated three times per second and are referenced to ITS-90. In addition to the actual temperature, the instruments calculate statistics in real time – minimum, maximum, average, range, T1−T2 and standard deviation – and show the elapsed run time of the statistics. A probe offset function allows the reading to be corrected for a particular sensor.
Accuracy is ±(0.04 % of reading + 0.3 °C). The 4-digit LCD with backlight and function annunciators uses auto-resolution: 0.1° below 1000° and 1° above, in °C, °F or K.
The meters are certified intrinsically safe to ATEX and IECEx (Ex ia IIB T4 Ga) and to UL for Class I Division 1 Groups C and D (T4) and Zone 0 AEx ia IIB T4. They are built to MIL-PRF-28800F Class 2 for shock, drop and vibration: random vibration 10–500 Hz at 0.03 g²/Hz, 30 g half-sine shock and four drops from 1 m onto concrete.
Power comes from three AA alkaline cells (4.5 V DC), giving a battery life of about 2000 hours. The operating temperature range is −20 to 50 °C, humidity 5 to 95 % RH at 10 to 30 °C, and altitude up to 15,000 ft. The housing measures 193 × 84 × 28 mm; the 921B weighs 300.9 g and the 922B 303.2 g with batteries. CE and RoHS conformity are declared; the instruments are made in the USA.
Options include a factory-installed tilt stand, magnet and hanger, and calibration with a statement of traceability.
Applications named for these thermometers are petrochemical plants, fuelling stations, aircraft maintenance, custody transfer operations, semiconductor facilities, pharmaceutical plants and food facilities.
When enquiring, please state the model (single or dual input), the thermocouple type you use, any options and whether a traceable calibration is required.
921B, 922B
Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.