Surent G480
Flow

Turbine & positive displacement meters
The HHF142 series is a handheld rotating metal vane anemometer kit for measuring air velocity and calculating volume flow in ducts. The kit includes the probe, the cables and a NIST calibration certificate, and the instrument is intended for air and clean gases.
Air speed is measured with a rotating metal vane: the HHF142A has a 25 mm (1 in) vane and the HHF142B a 70 mm (2 3/4 in) vane. Once a duct size has been entered, the instrument calculates the volume flow automatically. Up to ten different duct sizes can be stored and recalled. Low-speed sensitivity is stated as a feature of the design.
Accuracy is ±1.0 % of reading ±1 digit, and the resolution is 1 FPM or 0.01 m/s. Calculated volume flow is displayed up to 9999 CFM. The response time is 0.5 seconds. Temperature is measured with a type K thermocouple or a thermistor.
The probe can be used from −20 to 100 °C, while the instrument itself operates from 0 to 50 °C. Readings are shown on a four-digit backlit LCD. The instrument runs on AA alkaline batteries with a battery life of about 150 hours. It measures 6.5 × 3.25 × 1.5 in, and the probe is connected with a 5 ft cable; a 10 ft cable option is available. CE, UKCA and RoHS markings are stated.
Optional outputs include USB, 0 to 5 V DC, 4–20 mA, RS-232 and Bluetooth. Versions are identified by suffixes: -V for the 0–5 V DC voltage output, -USB for USB communication and -PB for a protective boot with splash-proof seals, for example HHF142B-V or HHF142B-PB. Replacement probes are available as HHF140A-RP and HHF140B-RP.
Applications named for the instrument are HVAC, aerospace development, industrial process airflow and fluids research. When you enquire, please state the vane size you need, the required output option, the cable length and whether a protective boot should be included.
HHF142A, HHF142B, HHF142A-V, HHF142B-V, HHF142B-PB, HHF142B-V-10FT, HHF140B-RP, HHF140A-RP, HHF140B-CABLE, HHF140-USB-CABLE, HHF140-V-CABLE, HHF140-232-CABLE, HHF140B-T-CABLE, MN1500-4
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.