The HHM-EX540 Series consists of heavy-duty industrial multimeters designed for rugged environments. These true-RMS instruments measure DC and AC voltage, current, resistance, capacitance, frequency and temperature and are built to withstand water, drops and electrical surges in industrial use.
Three models are available. The HHM-EX505 has a 4000-count display and a basic accuracy of 0.5 %, the HHM-EX520 a 6000-count display and 0.09 %, and the HHM-EX530 a 40,000-count display and 0.06 %. A data acquisition mode is provided, and NIST-traceable calibration is available (CAL-3-HHM).
Across the series, DC and AC voltage is measured from 0.01 mV to 1000 V, and DC and AC current from 0.01 µA to 20 A. Resistance ranges cover 0.01 Ω to 60 MΩ and capacitance 0.001 nF to 40 mF. Frequency is measured from 5 Hz to 1 kHz for electrical signals and from 0.001 Hz to 100 MHz for electronic signals. Temperature can be measured from −45 to 750 °C (−50 to 1382 °F), and duty cycle from 0.1 to 99.9 %. True-RMS measurement gives correct readings for non-sinusoidal waveforms. Values are shown on a large backlit LCD.
The enclosure is waterproof to IP67 and has a double-molded, drop-proof design tested to 2.9 m. All models have 1000 V input protection on all functions and surge protection rated at 8 kV peak per IEC 61010. The safety rating is CAT IV 600 V. The meters carry CE and UL marks and comply with RoHS.
Power comes from a 9 V battery, and an auto power off function saves the battery when the meter is left switched on. The instrument measures 184 × 83 × 57 mm (7.25 × 3.25 × 2.25 in) and weighs 349 g.
The series is intended for industrial applications and heavy-duty use. Please state the model and whether NIST-traceable calibration is required in your enquiry.
HHM-EX505, HHM-EX520, HHM-EX530, CAL-3-HHM
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.