Electrical test & measurement

Current & voltage transducers
The TAS-321DG is a microcontroller-based AC transducer for bidirectional current measurement on AC networks. As an alternative, it can be configured to measure active or reactive power on three-phase networks using only two phases. It converts the measured AC quantity into a DC current or voltage output signal for PLCs, PCs, microprocessor-based controls, indicators and alarm units.
The transducer measures sinusoidal alternating voltage and/or current signals and generates an output signal proportional to the measurement. It has no mechanical parts, which gives excellent calibration stability. The output characteristic can be configured with up to three slopes.
Measurement accuracy is class 0.5. Nominal measuring currents are 0.75, 1.5, 3.0 and 6.0 A, with a measuring range of 0 to 200 % of In. For power measurement, nominal voltages are 73, 140, 254 and 400 V phase to neutral or 127, 240, 440 and 690 V phase to phase, with a range of 30 to 120 % of Un. The frequency range is 30…45…65…80 Hz, and the response time is below 150 ms, typically 125 ms.
The auxiliary supply can be AC, with ratings from 57.7 V up to 690 V AC ±20 %, or DC with 24, 48, 110 or 220 V DC (−25/+30 %). The nominal ambient temperature range is −10 to 55 °C, the operating range −25 to 70 °C and the storage range −40 to 70 °C. The housing is IP40 and the terminals IP20. The transducer conforms to IEC 688, DIN 40040, EN 61000-6-1 to -4 and EN 60529.
The compact housing mounts on a 35 mm DIN rail, on a panel or with two 4 mm screws; a clearance of at least 50 mm between transducers is required. Devices are delivered pre-configured to customer data or unconfigured for setting with a PC tool; a PC configuration kit and extra labels are available. Listed versions include customised units with AC or DC auxiliary supply for current, for active power (1W2) or for reactive power (1VAr2), and unconfigured units with AC or DC supply.
Applications named for the transducer are power generation and marine and offshore installations, including commercial vessels, offshore supply vessels, pleasure boats, harbour and inland vessels, passenger ships and ferries, offshore platforms and rigs, and fishing vessels.
Please state the measured quantity, input ratings, output signal, auxiliary supply and quantity when enquiring.
2962010000.01, 2962010000.02, 2962010000.03, 2962010000.04, 2962010000.05, 2962010000.06, 2962010000.07, 2962010000.08, 2961860010.03, 2961860010.04
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.