Surent G480
Flow

Ultrasonic flowmeters
InnovaSonic 210i is a portable, battery-powered ultrasonic flow meter with clamp-on transducers for field measurement of liquids in pipes up to 236 inches (6000 mm). The transducers are fixed to the outside of the pipe, so no pipe cutting and no process shutdown are needed; installation takes place while the plant is running, and setup takes five minutes or less.
The meter uses universal transit-time technology. Ultrasonic signals are sent alternately with and against the flow stream, and the difference in their travel times is used to determine the liquid velocity. The measurement is independent of the conductivity of the liquid.
The meter covers pipe sizes from 0.6 to 236 inches (15 to 6000 mm) and flow velocities from 1.6 to 40 ft/s (0.49 to 12 m/s), with an accuracy of ±1.0 % of reading over this range and a repeatability of ±0.3 % of full scale. The permissible pipe-wall temperature is −40 to 80 °C; the handheld transmitter operates at ambient temperatures from −10 to 50 °C.
The handheld transmitter has a display and a 4–20 mA output and records data to a 1 GB SD card, so a measurement campaign can be logged and evaluated later. It is powered by an 11 V DC rechargeable lithium-ion battery for up to 10 hours of operation. The transmitter enclosure is rated NEMA 13 (IP54), the encapsulated transducers IP68. Transducers are mounted with magnetic racks; the standard cable length is 5 m, and cables up to 30 m are available. The transmitter weighs 0.6 kg and each transducer 0.4 kg. The meter is REACH compliant.
Options include a NIST-traceable certificate, longer cable lengths and insertion transducers.
Stated applications are flow audits, leak detection, HVAC monitoring, fuel and oil consumption measurement and offshore applications. Please tell us the pipe diameters and materials, the liquid, the expected flow velocity and pipe-wall temperature, and whether a traceable certificate is required.
210-16
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.