Heinrichs Messtechnik KDS / BGK
Heinrichs Messtechnik

KDS / BGK all-metal variable area flowmeters for low flow rates

Variable area flowmeters

Manufacturer
Heinrichs Messtechnik
Model
KDS / BGK
Instrument type
Variable area flowmeters
Measuring principle
float in conical tube, magnetic tracking system
Range, water
0.1–1 l/h up to 20–200 l/h
Range, air
5–50 Nl/h up to 600–6000 Nl/h
Accuracy
±3 % (qG 50 to VDE/VDI 3513)
Repeatability
±1.0 % of upper range value
Pressure rating
PN 40 (KDS-K, KDS-C, BGK); PN 63 (KDS-S), optionally higher
Process temperature
−40 to +130 °C without limit switches; −25 to +100 °C with electrical output
Ambient temperature
−25 to +70 °C
Output
4–20 mA, 2-wire (KDSE / KDS-E); 1 or 2 inductive limit switches
Pressure loss
water 6–95 mbar; air 6–28 mbar
Material
stainless steel 1.4404 / 1.4571 (316L / 316Ti)
Process connections
1/4" NPT female; flanges EN 1092-1, ASME B16.5; compression fittings 6–15 mm
Protection
IP65
Ex protection
e.g. II 2G Ex ia IIC T6-T4 Gb; II 2D Ex ib IIIC T135 °C Db
Approvals
ATEX, IECEx, SIL, PED, CE
Request a quote
Review enquiry

The KDS and BGK are all-metal variable area flowmeters for measuring and monitoring low flow rates of liquids and gases in pipes. The all-metal construction in stainless steel 1.4404 (316L) provides corrosion resistance, and the flow rate is indicated locally on an analogue indicator or transmitted by an electronic module.

The meters work on the float principle. The fluid flows upwards through a conical measuring tube and lifts a float until equilibrium is reached; the float position corresponds to the flow rate. A magnetic tracking system transfers the position through the tube wall to an analogue pointer or, in the KDSE / KDS-E versions, to an electronic transmitter that generates a 4–20 mA signal. KDS-R versions include a differential pressure regulator that keeps the flow constant despite pressure changes.

For water, measuring ranges extend from 0.1–1 l/h up to 20–200 l/h, and for air from 5–50 Nl/h up to 600–6000 Nl/h. Accuracy is ±3 % (qG 50 according to VDE/VDI 3513), and repeatability is ±1.0 % of the upper range value. For the KDS-R, the additional inaccuracy is ±1.7 % and the regulator deviation ±5.0 % of the upper range value. Pressure loss is 6–95 mbar on water and 6–28 mbar on air.

The 4–20 mA output is two-wire. One or two inductive limit switches can be fitted, and an M12 plug socket is used for connection. The KDS-K, KDS-C and BGK are rated PN 40 and the high-pressure KDS-S PN 63, with higher ratings optional. Process temperature is −40 to +130 °C without limit switches and −25 to +100 °C with electrical output; ambient temperature is −25 to +70 °C. Ingress protection is IP65.

Connections are 1/4" NPT female threads, flanges to DIN EN 1092-1 or ASME B16.5 on the BGK, and compression fittings for 6 to 15 mm tube. Explosion-proof versions carry ATEX and IECEx approval, for example II 2G Ex ia IIC T6-T4 Gb and II 2D Ex ib IIIC T135 °C Db, and SIL conformity to IEC 61508 is available. PED and CE are also listed.

Variants are the KDS-R with regulator, the wall-mounting KDS-C, the high-pressure KDS-S and the flanged BGK. Installation, commissioning and maintenance must be carried out by qualified technicians; cleaning requires a pressureless, cooled pipeline. Industries named include chemical and petrochemical, oil and gas, food, pharmaceutical, medical and laboratory. Please send the medium, flow range, pressure, temperature and connection with your enquiry.

Part numbers · 8

KDS, BGK, KDS-R, KDS-C, KDS-S, KDS-K, KDSE, KDS-E

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.