
Surent G480
Flow

Variable area flowmeters
KSK and KSM are variable area flowmeters with plastic measuring tubes for measuring and monitoring the flow of liquid or gaseous products in closed, vertical pipes. The KSK series covers the smaller flow ranges, the KSM series the larger ones. Applications named for the instruments are cooling circuits, water treatment, plant engineering and air flow measurement.
Both series work on the suspended float principle. The medium flows from below through a conical tube and lifts a float; the float height corresponds to the flow rate, which is read directly against a scale. For gases, scales are provided for different pressure conditions from 0 to 8 bar relative. For switching tasks, adjustable limit switches can be fitted as bistable reed contacts or electronic contacts, in versions without contact or with one or two contacts.
For water, the KSK covers ranges from 1.5–11 l/h up to 100–1,000 l/h, the KSM from 15–150 l/h up to 8,000–60,000 l/h. For air, KSK ranges extend from 0.15–0.45 Nm³/h up to 20–105 Nm³/h and KSM ranges from 0.8–5 m³/h up to 300–2,500 m³/h. KSK accuracy is class 4 according to VDI 3513; KSM accuracy is ±2 % of full scale.
The KSK measuring tube is made of Trogamide, polysulfone or PVDF and is rated PN10 with a maximum temperature of 140 °C. The KSM tube is Trogamide-T or polysulfone, rated 16 bar, with a maximum of 60 °C for Trogamide and 100 °C for polysulfone. The materials give shock resistance, corrosion resistance and high chemical resistance. KSK connections are G 1/4 to G 1 male threads or glue-in connections DN10 to DN25; the KSM is available from 1/2 to 3 1/2 in, with PVC Rp female threads, malleable cast iron G female threads, PVC flanges DN 25 to DN 65 and PVC glue-in connections Da32 to Da75. Protection is IP65.
The instruments are CE marked and conform to the Pressure Equipment Directive 2014/68/EU, the Low Voltage Directive, the Machinery Directive and RoHS, with safety to EN 61010-1. The design is simple, robust and service-friendly; support bracing should be installed where needed to avoid mechanical stress, and the measuring tube should be protected against external damage.
Please send the medium, flow range, pressure, temperature, connection type and the number of contacts required.
KSK, KSM
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.