VVB3
Mechanical & physical measurement

Load cells & force transducers
LCM204 and LCM214 are high-accuracy miniature universal load cells for tension and compression applications. The surface-mount sensors are built into a compact stainless steel body of 51 mm diameter and 39.6 mm height, which makes them suitable for test stands and difficult locations where space is limited.
The load cells work on the strain gauge bridge principle and deliver a rated output of 2 mV/V. They are excited with 10 V DC, with 15 V DC as the maximum. The input resistance is at least 350 Ω and the output resistance 350 ± 10 Ω. Each load cell is calibrated in tension with a five-point NIST-traceable calibration, and interchangeability is 1.0 %.
Capacities range from 100 N to 50,000 N in the metric versions, for example LCM204-100N, -500N, -1KN, -5KN, -10KN and -20KN. Linearity is ±0.15 %, hysteresis ±0.1 % and repeatability ±0.05 %; zero balance is within ±2 %. The operating temperature range is −46 to 107 °C, and the compensated range is 16 to 71 °C.
The stainless steel construction is protected to IP65. The design is FM approved as intrinsically safe. Two connection styles are offered: the LCM204 has a 3 m (10 ft) four-conductor shielded cable, while the LCM214 has a twist-lock connector, used with the PT06F10-6S mating connector.
Metric (LCM204/LCM214) and imperial (LC204/LC214) models are available, the imperial versions with capacities from 25 lb to 10,000 lb. Accessories include REC-012F and MREC-M12F rod ends for introducing the load, and compatible panel meters such as DPIS, DP41-S and DP25B-S for direct display of force.
Typical applications are test stands, industrial and commercial weighing and general force measurement tasks, especially where only little installation space is available.
Please send the required capacity, cable or connector version and any accessories such as rod ends or a display meter with your enquiry.
LCM204-100N, LCM204-200N, LCM204-500N, LCM204-1KN, LCM204-2KN, LCM204-5KN, LCM204-10KN, LCM204-20KN, LCM204-50KN, LCM214-100N, LCM214-200N, LCM214-500N, LCM214-1KN, LCM214-2KN, LCM214-5KN, LCM214-10KN, LCM214-20KN, LCM214-50KN
Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.