Surent G480
Flow

Electromagnetic flowmeters
The MIM is a robust, all-metal magnetic inductive flow meter for precise measurement of small to medium flows of conductive liquids in challenging industrial environments. It is used in pharmaceuticals, water treatment, food and beverage production and chemical processing, and it holds drinking water approvals (WRAS, DVGW).
The meter works on the principle of electromagnetic induction: when a conductive liquid flows through a magnetic field, a voltage is induced that is directly proportional to the flow velocity. From this voltage and the pipe cross-section, the MIM calculates the volumetric flow. The liquid must have a conductivity of at least 20 µS/cm. Flow can be measured in both directions, and the device includes temperature compensation and a dosing function.
Measuring ranges extend from 0.01 l/min up to 650 l/min, depending on the size. Accuracy is ±(0.8 % of reading + 0.5 % of full scale), repeatability ±0.2 % of full scale, and the response time t90 for flow is below 100 ms. A Pt1000 sensor additionally measures the medium temperature with an accuracy of ±2 °C at flow velocities above 0.2 m/s and a response time below 20 s. Medium temperature may be −40 to +140 °C and pressure up to 16 bar.
The housing is stainless steel 1.4404, and a rotatable colour TFT display shows the measured values. Two configurable outputs provide switching, pulse, frequency, alarm or 4–20 mA analogue signals and the IO-Link interface is connected via an M12 × 1 four-pin connector. Protection is IP67.
Process connections range from G 1/4 to 2″ NPT, including G 1/2, G 3/4 and 3/4″ NPT, with FKM or EPDM seals. Compact versions and remote versions are available; remote versions use PVC or ETFE cables and are supplied with wall mounting brackets. The meter carries CE marking and complies with the Pressure Equipment Directive 2014/68/EU, EN IEC 61326-1 and EN 60529.
The meter can be mounted in any direction: vertical, horizontal or in rising lines. Inlet and outlet pipes should be secured mechanically at 50 mm from the device, and plastic pipes require earthing.
Please send the liquid, its conductivity, the flow range, the process connection and the required outputs with your enquiry.
MIM, MIM-12, MIM-13, MIM-12 15H G5 C3T 0, ERS-ZOK-023618, ZUB-MIM225128, ZUB-AD2G20N15, ZUB-AD2G20P20, ZUB-AD2U20P15, ZUB-AD2G15N15, ZUB-AD2G15N08, ZUB-AD2G15P15, ZUB-AD2G08P08, ZUB-AD2G25T25, ZUB-AD2G25N25, ZUB-AD2G25N20, ZUB-AD2U25P15, ZUB-AD2U25P20
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.