Surent G480
Flow

Variable area flowmeters
The MMF-10-TMV is a Mini-Master variable area flowmeter from Series-MM for measuring and adjusting small flow rates. This model is calibrated at the factory for air at 1 atm and covers a range of 1 to 10 SCFH. An integrated top mount valve allows the flow to be set directly at the meter.
The measuring principle is that of a classic rotameter. A float moves inside a tapered tube; as the flow increases, the float rises to the point where the annular gap around it lets the flow pass, and its position is read on a calibrated scale. The scale length is 1.5 in, and stated accuracy is ±10 %.
The flowmeter has 1/4 in barbed fittings for connection to flexible tubing. The proof pressure is up to 10 psi, and the maximum operating temperature is 125 °F (approximately 52 °C). The meter is very light, weighing about 0.5 oz (approximately 14 g). It needs no power supply.
The device can be mounted in a panel or on a surface and must be installed vertically so that the float reads correctly. It complies with the RoHS II directive 2011/65/EU.
Within the Series-MM range, other versions are available with gas flow ranges up to 300 SCFH, with various liquid flow ranges, with a bottom mount valve or without a valve. These versions share the compact Mini-Master format.
Applications named for the Mini-Master series are dialysis, ozone generation, marine reef tanks and water clarification. When enquiring, please state the medium, the required flow range and the valve position, or confirm that the MMF-10-TMV with a top mount valve and 1 to 10 SCFH air calibration is the version you need, together with the required quantity.
MMF-10-TMV
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.