EDT 96
Pressure

Differential pressure transmitters
The MSXP-W20-PA-LCD is a wall-mount differential pressure transmitter with a 4-digit LCD and universal current and voltage outputs. It measures low differential pressures of air and non-combustible, compatible gases and is used for building pressure monitoring, filter monitoring, clean room pressure control and VAV system airflow.
The transmitter measures differential pressure in a range of 125 Pa and can be set for unidirectional or bidirectional measurement, covering −125 to +125 Pa in the bidirectional mode. The output is either a linear pressure signal or, with square root extraction, a linear velocity signal for flow calculation. Accuracy is ±1 %, with ±0.5 % FSO stated in the accuracy detail, and long-term stability is ±1 % FSO per year. The burst pressure is 6 psi.
Outputs are field selectable between 4–20 mA, 0–5 V DC and 0–10 V DC. The current output is used in 2-wire connection with a loop resistance of 0 to 1250 Ω; the voltage outputs use 3-wire connection with a minimum load resistance of 1 kΩ. The 4-digit LCD shows the measured value on site.
The housing is rated IP66 and NEMA 4X, is made of material rated UL94 V-0 and is plenum rated to UL 2043. The electrical connection is a 1/2″ NPS female conduit entry with a screw terminal block, and pressure is connected with stepped barb fittings. The transmitter is not position sensitive, and the maximum operating temperature is 70 °C. It is CE marked.
This model belongs to the MSX Pro series and combines wall mounting, the LCD display and the bidirectional 125 Pa range in one ready-to-install unit.
To confirm the selection, please tell us the pressure range, whether bidirectional measurement is required, the output signal and the application, for example filter or room pressure monitoring.
MSXP-W20-PA-LCD
Specify whether the reference is gauge, absolute or differential pressure. Include the normal span and the largest pressure the instrument may see.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.