Surent G480
Flow

Variable area flowmeters
The MT3750 Series is a compact metal tube variable area flowmeter for gas and liquid measurement in demanding environments with high pressures, high temperatures and hazardous areas. It is designed as a drop-in replacement for glass tube meters where a more rugged instrument is required.
The meter works on the variable area principle and gives a clear local flow indication. Its rugged stainless steel construction withstands a maximum operating pressure of 276 bar (4000 psi) and operating temperatures from −50 to 204 °C. Optional electronic outputs make the reading available for remote monitoring.
The series is aimed at low flows, including an extra-low flow (ELF) capability. Liquid flows are measured up to 100 l/h (26 gph) of water and gas flows up to 3.1 m³n/h (110 scfh) of air. Accuracy is ±3 % of full scale, corresponding to class 2.5 to VDI/VDE, or ±5 % of full scale, class 4, for the quick-ship versions. Repeatability is better than 1 % of full scale.
Options include a 4–20 mA transmitter, reed switch alarms and inductive alarms. For flow setting, the meter can be configured with a needle valve or a flow controller. Connections are 1/4 in NPT female integral, 1/4 in or 6 mm tube compression with adapter, and flanged versions.
Ingress protection is IP65, IP66, IP67 and NEMA 4X. The meter is approved for hazardous areas Class 1 Div 1 and Class 1 Div 2 as well as Zone 1 and Zone 2, and complies with EU REACH. Versions for offshore duty are available.
Applications named for the MT3750 include process analysers, chemical injection, purge gas and liquid metering, rotating equipment flow measurement, burner control, gas chromatography and high-pressure offshore applications.
Configurations are defined by an order code, for example 3750C-A-1-D-A-A-0 or 3750C-ABCDEF-1-BCD-EFGHJK-A-0.
With your enquiry, please send the medium, flow range, operating pressure and temperature, connection type, hazardous area classification and any required options such as transmitter, alarms or needle valve.
3750C-0-11A-AA, 3750C-0-11B-AA, 3750C-A-1-B-J-A-0, 3750C-A-1-D-A-A-0, 3750C-A-1-D-B-A-0, 3750C-A-1-D-E-A-0, 3750C-A-4-D-A-A-0, 3750C-A-4-D-E-A-0, 3750C-A-5-A-J-A-0, 3750C-ABCDEF-1-A-A-A-0, 3750C-ABCDEF-1-A-A-A-A-D, 3750C-ABCDEF-1-BCD-A-A-0, 3750C-ABCDEF-1-A-EFGHJK-A-0, 3750C-ABCDEF-1-BCD-EFGHJK-A-0, 3750C-ABCDEF-1-D-A-A-A-D, 3750C-ABCDEF-1-V3-A-A-A-0, 3750C-ABCDEF-2-A-A-A-0, 3750C-ABCDEF-2-A-EFGHJK-A-0, 3750C-ABCDEF-2-BCD-EFGHJK-A-0, 3750C-ABCDEF-3-BCD-EFGHJK-A-0, 3750C-B-1-A-A-B-0, 3750C-F-1-3-A-A-0, 3750C-G-1-E-A-A-0, 3750C-G-1-E-EFGHJK-A-0
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.