Heinrichs Messtechnik NGS
Heinrichs Messtechnik

NGS dual magnet float level switch

Float & magnetic level indicators

Manufacturer
Heinrichs Messtechnik
Model
NGS
Instrument type
Float & magnetic level indicators
Principle
float with repelling magnets, microswitch with snap action
Switching element
1 microswitch, 1 NO and 1 NC contact
Switch rating
250 V AC 10 A; 220 V DC 0.6 A
Switch rating, Ex
250 V AC 2.5 A; 220 V DC 0.3 A
Medium temperature
up to 250 °C (NGS-2: −40…+250 °C)
Nominal pressure
16 bar (NGS-23); PN 25; PN 40 (DN 80/100)
Min. medium density
> 0.7 kg/dm³ (arm 0–200 mm) to 0.85 kg/dm³ (long arms)
Arm length
0 to 3000 mm
Wetted parts
stainless steel 1.4571; other materials by version
Housing
aluminium, colour coated; carbon steel; stainless steel 1.4571
Process connection
92 mm square flange PN 25; 2″ BSP; 2″ NPT; DIN flanges
Electrical connection
M20 × 1.5 or integrated cable
Ingress protection
IP65; IP68 submersible (max. 20 m WC)
ATEX
II 1/2 G Ex de mb IIC T6…T2 Ga/Gb
Differential
adjustable (NGS-23) or fixed (NGS-21)
Request a quote
Review enquiry

NGS is a dual magnet float level switch for controlling and monitoring liquid levels in open and closed vessels. It is designed for secure, wear-free and sensitive switching and detects even very small changes in liquid level. The switch needs no auxiliary power and no regular maintenance, and it is built for tough environments, including potentially explosive atmospheres.

The float is mounted on an arm. As the level rises and falls, the inclination of the float changes and deflects a permanent magnet. This magnet repels a rotatable opposing magnet, which produces a forced snap-action effect and operates a microswitch through a plunger. In the Ex version the contacts are protected by flameproof enclosure 'd' and encapsulation 'mb'.

The switching element is one microswitch with one normally open and one normally closed contact, rated 250 V AC / 10 A and 220 V DC / 0.6 A; Ex versions are rated 250 V AC / 2.5 A and 220 V DC / 0.3 A. The differential (hysteresis) is adjustable on NGS-23 and fixed on NGS-21. Medium temperatures range up to 250 °C depending on the model, for example −40 to +250 °C for NGS-2 and −20 to +80 °C for NGS-4. Nominal pressure is 16 bar for NGS-23 and PN 25 or PN 40 for flanged versions. The medium must have a minimum density between more than 0.7 kg/dm³ for short arms and 0.85 kg/dm³ for arm lengths of 1000 to 3000 mm.

Wetted parts are made of stainless steel 1.4571, with rubber or silicone rubber protection sleeves on some versions and carbon steel, stainless steel 1.4404 or steel 1.7218 as alternatives. Housings are colour-coated aluminium, carbon steel or stainless steel 1.4571. Process connections include a 92 mm square flange PN 25, 2″ BSP and 2″ NPT threads and DIN flanges. Standard versions (NGS-2, -5, -6) have an M20 × 1.5 cable entry and IP65; submersible versions (NGS-4, -7, -8) have an integrated cable and IP68 up to 20 m water column. The ATEX version is marked II 1/2 G Ex de mb IIC T6…T2 Ga/Gb.

Versions are available for horizontal mounting (NGS-_1, NGS-_2), top mounting (NGS-23) and side mounting (NGS-21, NGS-22, NGS-41), with arm lengths from 0 to 3000 mm. During installation the float must move freely without touching the walls or the bottom of the vessel.

Typical tasks are minimum or maximum monitoring of liquids in open and closed vessels in tough and explosive environments. Please send the medium, density, temperature, pressure, mounting position and required process connection with your enquiry.

Part numbers · 15

NGS-_1, NGS-_2, NGS-2, NGS-21, NGS-22, NGS-23, NGS-4, NGS-41, NGS-5, NGS-51, NGS-6, NGS-61, NGS-7, NGS-8, NGS-2100 Ex

Industry applications

Selection notes

Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU