Heinrichs Messtechnik NMC
Heinrichs Messtechnik

NMC capacitive level transmitter for liquids

Capacitive level sensors

Manufacturer
Heinrichs Messtechnik
Model
NMC
Instrument type
Capacitive level sensors
Measuring principle
capacitive, for liquids up to 1000 pF
Probe length
265…4000 mm
Measuring error
< 1.5 % of probe length
Medium temperature
−20…+90 °C; −20…+200 °C (NMC-H)
Ambient temperature
−10…+60 °C
Pressure
−1…+30 bar
Minimum dielectric constant
εr ≥ 1.5
Output
4–20 mA, 2-wire
Display
4-line alphanumeric LCD, % and mA
Power supply
10…35 V DC; 12…30 V DC for ATEX
Process connection
G 1 male (NMC-N, -H, -T); G 2 male (NMC-S)
Housing
polycarbonate, IP65
Electrical connection
1 × M20 × 1.5
ATEX marking
Ex II 2/1 GD Ex ia IIC T4 Gb/Ga; Ex ia IIIC T85 °C Db/Da
Request a quote
Review enquiry

NMC is a capacitive level transmitter for continuous measurement of liquid level in tanks. It consists of a measuring probe and a connecting head with a plug-in evaluation module, and it converts the level directly into a 4–20 mA two-wire signal that can be connected to a controller, a PLC or a display unit.

The measuring principle is capacitive. The probe and the tank wall form a capacitor in which the liquid acts as the dielectric. As the level rises or falls, the capacitance changes; the electronics convert this change into the current signal and show the level as a percentage. The device is designed for liquids up to 1000 pF and requires a medium with a dielectric constant of at least εr = 1.5. There are no mechanically moving parts, and maintenance is simplified by the plug-in module.

Probe lengths range from 265 mm to 4000 mm, and the measuring error is less than 1.5 % of the probe length. The standard versions work with medium temperatures from −20 to +90 °C; the high-temperature NMC-H version is rated from −20 to +200 °C. The permissible process pressure is −1 to +30 bar, and the ambient temperature range is −10 to +60 °C.

The output is 4–20 mA in two-wire technology. A four-line alphanumeric LCD shows the level in per cent and the output current in mA, each with one decimal place. The supply voltage is 10 to 35 V DC, or 12 to 30 V DC for the ATEX version; the cable is connected through one M20 × 1.5 entry.

The housing is made of polycarbonate with IP65 protection. Process connections of NMC-N, NMC-H and NMC-T are made of stainless steel 1.4305 with a G 1 male thread; NMC-S has a PVDF connection with a G 2 male thread. Adapters with G 1¼ and G 1½ threads and a welding-in sleeve with 40 mm outside diameter (not for NMC-S) are available. The ATEX version is marked Ex II 2/1 GD Ex ia IIC T4 Gb/Ga and Ex ia IIIC T85 °C Db/Da and follows EN 60079-0, -11, -26 and -31; the device also carries CE marking.

Four models are offered: NMC-N, the standard version with a PTFE-coated stainless steel probe; NMC-H, the high-temperature version with a PTFE-coated probe; NMC-T with a reference pipe and an internal stainless steel sensor; and NMC-S, a two-probe sensor with PVDF connection and PVDF coating.

Typical media are water and water-like liquids, liquid food, chemical and aggressive liquids, oil and pharmaceutical liquids. Please send the required probe length, medium, temperature, pressure and whether an ATEX version is needed with your enquiry.

Part numbers · 4

NMC-N, NMC-H, NMC-T, NMC-S

Industry applications

Selection notes

Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments