LUMEL NMID33LITE
LUMEL

NMID33LITE three-phase MID energy meter, direct up to 100 A

Energy meters

Manufacturer
LUMEL
Model
NMID33LITE
Instrument type
Energy meters
Network
3-phase 4-wire, 3-phase 3-wire, 1-phase 2-wire
Current measurement
Direct, up to 100 A
Measurement
True RMS
Measured quantities
Active and reactive energy (imported/exported), apparent energy, current
Accuracy class
B (EN 50470-3), class 1 (IEC 62053-21)
Standards
EN 50470-3, IEC 62053-21, IEC 62053-23
Power supply
Self-powered from the measuring circuit
Display
Backlit 1-line, 8-digit seven-segment LCD
Tariffs
Up to four, selectable via digital inputs
Pulse outputs
Two S0
Terminals
Sealable
Housing
4 modules (72 mm), DIN rail
Approvals
MID, CE
Request a quote
Review enquiry

The NMID33LITE is a three-phase digital electricity meter for residential buildings, commercial facilities and light industry. It is the version of the NMID33 family without a serial communication interface. The meter is MID certified and works in 3-phase 4-wire, 3-phase 3-wire and 1-phase 2-wire systems.

Current is measured directly up to 100 A, so no external current transformers are needed, and the meter is powered from the measuring circuit itself. Measurement is True RMS. The meter records energy bidirectionally: active energy imported and exported, reactive energy imported and exported, as well as apparent energy and current. Values are shown on a backlit one-line, 8-digit seven-segment LCD.

Accuracy is class B according to EN 50470-3 and class 1 according to IEC 62053-21; reactive energy metering follows IEC 62053-23. Up to four energy tariffs can be used, with the active tariff selected through the digital inputs of the meter.

For transferring consumption data to external counters, data loggers or building management systems, the meter provides two S0 pulse outputs. The terminals can be sealed after installation to prevent tampering.

The housing is 4 modules (72 mm) wide and mounts on a standard DIN rail in distribution boards. The meter carries the MID certificate and a CE declaration of conformity.

Within the same family, the NMID33 adds an RS-485 interface with Modbus RTU and the NMID33MBUS an M-Bus interface; the LITE version offers the same metering functions without these interfaces.

The applications named for this meter are energy metering and sub-metering in residential buildings, commercial facilities and light industry, in single-phase or three-phase installations with currents up to 100 A.

When enquiring, please state the required quantity and whether a version with Modbus RTU or M-Bus communication would be preferred.

Part numbers · 1

NMID33LITE

Industry applications

Selection notes

Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU