DTL C
Electrical test & measurement

Power quality analysers
The Norma 4000 is a compact, high-precision power analyser for the development and testing of power electronics. It can be configured for one to three phases and is used on electric motors and inverter drive systems, lighting systems, transformers, switching power supplies and UPS, automotive components and in calibration and test laboratories.
The analyser is built on a high-bandwidth architecture that measures single- or three-phase voltage and current precisely, performs FFT analysis and calculates power and derived values. Signals can be connected directly, via shunts or through voltage and current transducers. Harmonics of voltage, current and power are calculated up to the 40th order and shown graphically, with up to three bar graphs at the same time. A digital oscilloscope mode displays up to three signals at sample level for a quick view of waveform and distortion, a vector display shows the phase angles of up to six signals to check correct connection, a recorder shows average values over time for trends, and an integration function measures energy with start/stop conditions and positive or negative direction.
Performance depends on the input module, called a power phase. The PP42 offers 0.2 % accuracy, 20 A current range, 341 kHz sampling and 3 MHz bandwidth; the PP50 0.1 %, 10 A, 1 MHz sampling and 10 MHz bandwidth; the PP54 0.1 %, 10 A, 341 kHz and 3 MHz; the PP64 0.03 %, 10 A, 341 kHz and 3 MHz. Voltage ranges extend from 0.3 V to 1000 V, and current can be measured directly from 0.03 mA up to 20 A. Input impedance is 2 MΩ / 20 pF and common mode rejection 120 dB at 100 kHz.
RS-232 and USB interfaces are standard, and PC software for data download, analysis and report writing is included. Options include an IEEE 488.2/GPIB interface, an Ethernet/LAN adapter, the PI1 process interface with eight analogue/pulse inputs and four analogue outputs, analogue/digital output channels and remote control via SCPI. Memory is 4 MB, expandable to 128 MB.
The instrument has a 5.7-inch colour display, operates from 85–264 V AC or 100–260 V DC and consumes about 40 VA. It is a bench unit of 150 × 237 × 315 mm and about 5 kg; a 19-inch rack mount kit, star point adapter, current binding post and internal printer are available. Safety rating is 1000 V CAT II (600 V CAT III) to EN 61010-1; working temperature is 5 to 35 °C, for indoor use only.
Please state the number of phases, the required power phase modules, interfaces and accessories when you send your enquiry.
3108534, 3108541, 3108552, 3108565, 3110957, 3110969, 3110978, 3108576, 3108583, 3108590, 3312894, 3108601, 3108612, 3108620, 3108635, 3108647, 3108658, 3108664, 3312934, 3108673, 3312941, 3108686, 3108699, 3108702, 3312952, 3312965, 3312976, 3108716, 3108725, 3312929, 3313044, 3312918, 3313003, 3313015, 3312907, 3108733, 3108740, 3312983, 3312990, 3108757, 3108769, 3313026, 3313032, 3024677, 3024689, 3024886, 3024899, 3024847, 3024858, 3024864, 3024873, 3024692, 3313059, 3313067, 3024661, 3024704, 3024650, 3024781
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.