LUMEL P18 / P18D
LUMEL

P18 / P18D humidity and temperature transducers with RS-485 Modbus RTU

Humidity & air temperature

Manufacturer
LUMEL
Model
P18 / P18D
Instrument type
Humidity & air temperature
Measured values
relative humidity, ambient temperature
Calculated values
dew-point temperature, absolute humidity
Output
analogue standard signal or digital
Interface
RS-485
Protocol
Modbus RTU
Display
LCD (P18D only)
Functions
min/max memory, programmable averaging time, individual linear characteristic
Configuration
via RS-485 with configuration software
Mounting
wall
Versions
P18 standard; P18D with LCD
Request a quote
Review enquiry

The P18 and P18D are transducers for continuous measurement of relative humidity and ambient temperature. They convert both quantities into standard analogue or digital signals, so that the climate in a room, store or technical area can be passed to a controller, recorder or building and process control system.

Besides the directly measured values, the transducers calculate further physical quantities: dew-point temperature and absolute humidity. Any of these quantities can be converted into the output signal according to an individually programmed linear characteristic, which allows the output range to be matched to the receiving device.

The transducers offer analogue standard signal outputs or a digital output. Digital communication uses an RS-485 interface with the Modbus RTU protocol. The same interface is used for programming: configuration is carried out from a PC with the configuration software, without opening the device.

Additional functions include storage of maximum and minimum values and programming of the measurement averaging time. The averaging time can be set to smooth short-term fluctuations, while the min/max memory records the extremes reached during the monitored period.

Two versions are available. The P18 is the standard version without a display. The P18D has an LCD display that shows the measured values locally, which is useful during commissioning and for operators checking conditions on site.

Both versions are designed for wall mounting. With suitable sensor shields they can be used in various ambient conditions. Measuring ranges, accuracy, output ranges and supply voltage are confirmed for the specific version together with the quotation, so that the transducer matches the receiving device.

Please state the required version (P18 or P18D), the output signal type and the quantities to be transmitted with your enquiry, so that the transducer can be configured and offered accordingly.

Part numbers · 2

P18, P18D

Industry applications

Selection notes

Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.