EDT 96
Pressure

Pressure transmitters
The PAX9 is a pressure transmitter for absolute and relative pressure measurement in industrial and marine environments. It acquires the pressure from systems such as diesel engines, pumps and hydraulic systems and converts it into a 4–20 mA or 0–10 V output signal. Versions are designated PA9 and PAG9 for relative pressure and PAA9 for absolute pressure.
The measuring cell and wetted parts are made of CrNi steel 316L or 13-8 PH steel. The design is vacuum-proof. The standard measuring range is 1 to 600 bar, and a special measuring range of 2 to 300 bar is also offered.
Accuracy is ±1 % of range or better, non-linearity ±0.5 % of range or better, non-repeatability 0.1 % of range or better and long-term drift ±0.1 % of range or better. The operating temperature range is −30 to +100 °C. Vibration resistance is 10 g at resonance to IEC 60068-2-6 and shock resistance 500 g to IEC 60068-2-27.
Two output versions are available: 4–20 mA in 2-wire connection with a supply voltage of 8 to 30 V DC, and 0–10 V DC in 3-wire connection with a supply voltage of 14 to 30 V DC. Electrical connection is made with an angular connector, a circular connector or a cable outlet.
Process connections are G1/4 B, 1/4-18 NPT or M14 × 1.5. Protection is IP65 or IP67, depending on the electrical connection. The transmitter weighs approximately 80 g. It carries the CE mark and is DNV-GL certified for offshore use. Further references include UL/EN/IEC 61010-1, UL/EN/IEC 60950-1, UL 1310 / UL 1585, the Pressure Equipment Directive 97/23/EC and the EMC Directive 2004/108/EC with EN 61326.
Applications named are shipbuilding, transport technology, machinery, diesel engines and hydraulic systems. Please state whether absolute or relative pressure is required, together with the measuring range, the output signal, the process connection and the electrical connection type in your enquiry, so that the correct article can be offered.
PA9-81-11I2A, PAG9-81-11I2A, PAA9-81-11I2A
Specify whether the reference is gauge, absolute or differential pressure. Include the normal span and the largest pressure the instrument may see.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.