Heinrichs Messtechnik PIT
Heinrichs Messtechnik

PIT magnetic-inductive insertion flow sensor for large pipes

Electromagnetic flowmeters

Manufacturer
Heinrichs Messtechnik
Model
PIT
Instrument type
Electromagnetic flowmeters
Principle
magnetic-inductive (Faraday's law), insertion type
Pipe size
DN 125–2000 (stainless steel/PTFE); DN 125–600 (PFA)
Nominal pressure
PN 16, ASME Cl 150/300; PN 40 (PFA)
Velocity range
1–10 m/s standard; 0.5–5 m/s special
Accuracy
±1.5 % of measured value + ±0.5 % of URV
Repeatability
±0.75 % of reading ± 0.25 % of URV
Min. conductivity
≥ 20 µS/cm
Process temperature
−40 to +150 °C
Ambient temperature
−40 to +60 °C
Transmitters
UMF2: 115/230 V AC or 24 V DC; UMF3: 90–253 V AC or 24 V DC
Outputs
4–20 mA (HART on UMF3), pulse, status
Electrodes
stainless steel; Hastelloy, tantalum, platinum options
Protection
IP65 / IP68
Ex marking
Ex eb ia IIC T3…T6 Ga/Gb
Approvals
ATEX, IECEx, NEPSI, DNV, TÜV, CE
Request a quote
Review enquiry

PIT is a magnetic-inductive insertion sensor for measuring volume flow in large-diameter pipelines. Instead of a full-bore meter, a sensor rod is inserted into the pipe through a weld-in socket, so the flow is measured without pressure loss and with a fast and economical installation. The sensor is suitable for pipes from DN 125 to DN 2000 and for electrically conductive liquids, slurries and pastes.

The measurement follows Faraday's law of electromagnetic induction. The sensor generates a magnetic field, and the conductive liquid flowing through it induces a voltage that is picked up by electrodes and is proportional to the flow velocity. The UMF2 or UMF3 transmitter processes this signal and provides standard outputs. The medium must have a conductivity of at least 20 µS/cm.

Stainless steel/PTFE sensors are used in DN 125 to DN 2000, PFA sensors in DN 125 to DN 600. The standard velocity range is 1 to 10 m/s, with a special range of 0.5 to 5 m/s. Accuracy is ±1.5 % of measured value plus ±0.5 % of the upper range value, and repeatability ±0.75 % of reading ±0.25 % of the adjusted upper range value. The process temperature range is −40 to +150 °C and the ambient range −40 to +60 °C. Nominal pressures are PN 16 and ASME Class 150/300, or PN 40 for PFA versions.

The UMF2 transmitter is powered with 115/230 V AC or 24 V DC and offers a galvanically isolated active 0/4–20 mA output, a passive pulse output and a status output. The UMF3 is powered with 90 to 253 V AC or 24 V DC and provides a passive 4–20 mA output with HART, a 1 kHz pulse output and a status output. The transmitter can be mounted integrally or remotely.

Protection is IP65 or IP68, and IP68 versions are available in standard and seawater-resistant execution. Electrodes can be ordered in Hastelloy, tantalum or platinum. Flanges follow EN 1092, ASME B16.5 and DIN 2512. For hazardous areas the sensor uses intrinsic safety 'i' and increased safety 'e' and is marked Ex eb ia IIC T3…T6 Ga/Gb; approvals include ATEX, IECEx, NEPSI, DNV and TÜV. A retractor device allows the sensor to be installed or removed under operating conditions without interrupting the flow. Straight runs of 10 DN upstream and 5 DN downstream are required.

Listed industries are chemical and petrochemical plants, onshore and offshore oil and gas, food and beverage, pharmaceuticals, water treatment and pulp and paper, including Zone 0, 1 and 2 areas. Please send the pipe size, medium, conductivity, pressure and required transmitter with your enquiry.

Part numbers · 10

PIT, PITE, UMF2, UMF3, PIT-520, PIT-580, PIT-571, PIT-S, PIT-A, PIT-U

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU