Surent G480
Flow

Ultrasonic flowmeters
Q.Sonic-max6 is an ultrasonic gas flow meter designed for custody transfer measurement of natural gas and other gases, including in installations where pipe layout and flow conditions are far from ideal. The meter measures with six direct acoustic paths arranged as three pairs of crossed X paths. By comparing transit times with and against the flow on each path, it determines the gas velocity in different parts of the cross-section and thus the complete flow profile, which gives high accuracy even with disturbed or swirling flow.
Typical measurement uncertainty is 0.5 % after zero-flow calibration, 0.2 % after high-pressure flow calibration and 0.1 % with additional linearisation; repeatability is 0.05 % or better. The meter has no moving parts, causes no pressure drop and measures in both directions. Optional internal pressure and temperature sensors allow the electronics to calculate the Reynolds number and to correct for changes of body diameter and path geometry at high pressure and temperature.
Sizes range from 3 to 24 inches (DN 80 to DN 600), with larger meters up to 56 inches available on request. Bodies up to 16 inches have a reduced bore with a 7° taper; from 18 inches they are full bore. Pressure ratings are ASME 150 to 900, up to 250 barg. The standard body material is low-temperature carbon steel ASTM A350 LF2, with other grades and stainless steel on request, supplied with EN 10204 3.1 certificates and 3.2 on request. The meter handles gases with a specific gravity from 0.55 to 1.5 and natural gas blends with up to 30 % hydrogen.
Transducers are titanium-encapsulated and intrinsically safe; a retraction tool allows them to be exchanged under pressure. The signal processing unit in a cast aluminium or optional stainless steel enclosure is certified to ATEX and IECEx Ex db ia [ia Ga] IIB+H2 T6 Gb and to FM Class I Division 1, with IP66 and NEMA 4X protection. It is powered with 24 V DC and communicates via RS-232, Ethernet and USB, Modbus RTU and frequency outputs; an Ethernet range extender is available for long distances. Cybersecurity follows ISA/IEC 62443. PC software provides configuration, diagnostics and health monitoring.
The meter carries MID approval for legal metrology in Europe and follows AGA 9. Typical uses are custody transfer in gas transmission and distribution, gas exploration, facilities with variable gas composition and high-pressure stations. Please send line size, pressure class, flow range and gas composition with your enquiry.
QS6M080, QS6M100, QS6M150, QS6M200, QS6M250, QS6M300, QS6M350, QS6M400, QS6M450, QS6M500, QS6M600, QS6M650, QS6M700, QS6M750, QS6M800, QS6M900
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.