Gems Sensors & Controls RLI-G
Gems Sensors & Controls

RLI-G guided wave radar level sensor, up to 24 m

Radar level transmitters

Manufacturer
Gems Sensors & Controls
Model
RLI-G
Instrument type
Radar level transmitters
Measuring principle
guided wave radar, TDR
Measuring range
up to 24 m (80 ft)
Accuracy
±5 mm (0.2 in)
Resolution
3 µA
Minimum dielectric constant
εr 1.4
Media temperature
−30 to +90 °C
Max pressure
40 bar (cable and rod probes); 16 bar (coaxial probes)
Output
4–20 mA + HART
Power supply
18–35 V DC
Ambient temperature
−30 to +60 °C; with display −20 to +60 °C
Housing
paint-coated aluminium, FPM seal; 316 SS
Process connections
1 in and 1-1/2 in BSP or NPT; 3 in 150# ANSI
Protection
IP67
Weight
2 kg (housing unit)
Request a quote
Review enquiry

The RLI-G is a continuous guided wave radar level sensor for marine and industrial tank level applications. It has no moving parts and determines the level of liquids, including clean and contaminated liquids, high-viscosity liquids, slurries and pulp, over measuring ranges up to 24 m (80 feet).

The sensor works on the time domain reflectometry (TDR) principle. Microwave micropulses are sent along a probe that extends into the tank; at the surface of the medium part of the energy is reflected back, and the distance to the surface is calculated from the flight time of the impulse. The sensor configures itself to the dielectric constant of the medium and handles media with a dielectric constant as low as 1.4.

Accuracy is ±5 mm (0.2 in), and the current output resolution is 3 µA. Media temperature can be −30 to +90 °C. The maximum pressure is 40 bar (580 psig) for cable and rod probes and 16 bar (232 psig) for coaxial probes. Ambient temperature is −30 to +60 °C, or −20 to +60 °C with display.

The output is 4–20 mA with HART, and the power supply is 18 to 35 V DC. An LCD display module shows the level locally; a plug-in graphic display module (GMD-100), configuration software and a HART-USB modem are available for setup and diagnostics.

The housing is made of paint-coated aluminium with FPM sealing and is rated IP67; wetted parts include 316 stainless steel. The housing unit weighs 2 kg. Process connections include 1 in and 1-1/2 in BSP or NPT threads and 3 in 150# ANSI flanges.

Several probe types are offered: mono cable, twin cable, mono rod, twin rod, coaxial pipe and segmented rod, with multiple mounting options. Required clearances depend on the selected probe, and stilling well options are available on request.

Applications named include marine and industrial tanks, high-viscosity liquids, conductive foams, slurries and pulp, LPG and LNG. Please send the medium, tank height, pressure, temperature and process connection with your enquiry.

Part numbers · 19

RLI-G-B-J-4-0-8-4, RLI-G-B-AA-4-1-19-4, RLI-G-B-AC-4-2-9-4, RLI-G-B-H-4-1-5-4, RLI-G-B-L-4-1-0-4, RLI-G-B-AF-4-1-2-4, RLI-G-B-H-4-2-4-4, RLI-G-B-W-4-0-8-4, RLI-G-B-B-4-1-0-4, RLI-G-B-J-4-2-4-4, RLI-G-B-J-4-0-9-4, RLI-G-B-AL-4-0-4-4, RLI-G-B-P-4-1-4-4, RLI-G-B-P-4-2-9-4, RLI-G-B-H-4-1-0-4, RLI-G-B-HS-4-3-1-4, RLI-G-B-AAS-4-3-2-4, RLI-G-B-AJ-4-1-1-4, RLI-G-B-AA-4-3-2-4

Industry applications

Selection notes

Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment