EDT 101
Temperature

Thermostats & temperature switches
The RTK5 is a compact limit value switch for temperature monitoring with NiCr-Ni type K thermocouples. It is designed for harsh environments and severe operating conditions and carries marine classification approvals, so it is used in particular in marine applications.
The device evaluates the millivolt voltage generated at the thermocouple tip. An integral reference junction compensates for the temperature at the terminals. When the signal reaches the limit value set on the drum scale, the integrated relay switches. The drum scale is tamper-proof. A broken-wire monitoring function detects an interrupted thermocouple circuit and signals it with an LED, and a second LED indicates the operating status.
Two measuring ranges are available: 0 to 600 °C for the RTK58 and 0 to 800 °C for the RTK59. Each is offered with the change-over contact working in closed-circuit current (RTK58, RTK59) or open-circuit current (RTK58-A, RTK59-A).
The output is a volt-free change-over contact with a maximum switching capacity of 30 W (1 A at 30 VDC or 0.5 A at 60 VDC) or 40 W (0.2 A at 220 VAC). The unit is supplied with 9 to 32 VDC. Electrical connection is by gold-plated DIN 46244 tab connectors A6.3 × 0.8.
The housing is made of green thermoplastic polyester with fire protection class V0 and is mounted on a TS32 G-rail or TS35 top-hat rail. The switch operates from −20 to +70 °C and up to 96 % humidity. It has been tested for vibration resistance of 15 g to IEC 60068-2-6 and shock resistance of 300 m/s² to IEC 60068-2-27, and for EMC to the IEC 61000-4 series, DIN EN 61000-6-2 and 6-4; DIN EN 50155 is also listed. The unit weighs 55 g. Approvals are DNV, BV and LR, plus CE marking.
Its compact and robust construction makes the RTK5 suitable for temperature monitoring in harsh environments, with marine applications named as the main field of use.
When enquiring, please specify the measuring range, closed-circuit or open-circuit version and the quantity.
RTK58, RTK58-A, RTK59, RTK59-A
Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.