Surent G480
Flow

Turbine & positive displacement meters
Type S077 is an inline sensor fitting with oval gears for flow measurement or dosing of high-viscosity liquids such as adhesives, honey or oil. It forms the hydraulic part of a flow measuring device and is combined with a separate transmitter of Type SE30, SE30 Ex, SE32, SE35 or SE36 to form a complete instrument.
The fitting works on the positive displacement principle. The flowing liquid drives two oval gears; their rotation generates a signal proportional to the flow velocity, which the transmitter converts into a volume flow rate using a specific K factor.
The fitting is available in nominal sizes DN 15 to DN 100. For liquids with a viscosity above 5 mPa·s the measuring range is 2 to 1200 l/min, and for liquids below 5 mPa·s it is 3 to 1000 l/min. The maximum dynamic viscosity is 1 Pa·s and the maximum particle size 250 µm. With teach-in calibration the measurement deviation is ±0.5 %; with the standard K factor it is ±1 %. Repeatability is ±0.03 %.
Body materials are aluminium, for fluid temperatures from −20 to +80 °C, or stainless steel 316L (1.4401), for −20 to +120 °C. Oval gears are made of PPS, PEEK, aluminium or 316L stainless steel, and seals are FKM or FEP/PTFE encapsulated. The maximum pressure depends on size: 55 bar for DN 15 and DN 25, 18 bar for DN 40 and DN 50, 12 bar for DN 80 and 10 bar for DN 100. Connections include internal threads 1/2, 1, 1 1/2, 2 or 3 in G or NPT, DIN PN 16 flanges of 25, 40, 50, 80 or 100 mm and ANSI 150 lb flanges of 1 to 4 in. The ambient range for operation and storage is 0 to +60 °C. The fitting complies with the CE requirements and the Pressure Equipment Directive 2014/68/EU.
Article numbers combine size, connection and material; for example 567223 is DN 15, G1/2, aluminium body, PPS gears and FKM seal, while 567224 is the stainless steel version with stainless gears and FEP/PTFE seal.
For correct measurement, the pipe must always be filled with liquid, without air bubbles or cavitation. Please state the liquid and its viscosity, flow range, pressure, temperature, connection and transmitter type when enquiring.
567223, 567224, 567225, 567226, 567227, 567228, 567229, 567230, 567231, 567232, 567233, 567234, 567235, 567237, 567239, 567241, 567243, 567244, 567245, 567247, 576582, 576583, 576580, 576578, 576581, 576579, 567249, 567250, 567251, 567252, 567253, 567254, 567741, 567742, 567743, 567744, 567745, 576600, 567747, 576602, 567754, 567755, 567756, 567757, 567758, 567759, 567760, 567761
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.