LDH313
Gas analysis

Oxygen analysers
This SIL2-capable oxygen analyser is a DIN-rail mounted unit for oxygen measurement in hazardous areas and safety instrumented systems. It is used for inertisation of centrifuges, reactors, mills, glove boxes and vent headers, in additive manufacturing, API pharmaceutical production, powder handling and hydrogen electrolysers.
The analyser works with zirconia or solid-state electrochemical oxygen sensors. Two microprocessors monitor each other continuously, which delivers fail-safe oxygen measurement and makes the device suitable for SIL2 applications according to IEC 61508. The sensor circuit is intrinsically safe (Uo = 6 V DC), with ATEX marking II (1) G [Ex ia Ga] IIC and II (1) D [Ex ia Da] IIIC, so the sensor circuit may extend into the hazardous area.
The measuring range is 0 to 25 % O2 with a resolution of 0.01 %. Accuracy is ±0.01 %, specified as ±0.02 % at 1 % O2 and ±0.01 % at 0.1 % O2. The response time is below 20 seconds, typically 12 seconds. The recommended sample flow is 100 to 500 ml/min, with 250 ml/min as the optimum.
The measured value is retransmitted as a 4–20 mA analogue signal, and an RS485 digital interface is provided. Configurable alarm relays switch at the set oxygen levels, and LCD and LED indicators show the reading and status. The alarm levels are programmed before delivery; customer access to the settings requires separate PC software. The analyser is powered from 24 V DC and consumes 1.5 W.
The housing is designed for DIN rail mounting, measures 70 × 100 mm and is rated IP20. It operates from −20 to 50 °C and 0 to 95 % RH non-condensing. Approvals include ATEX, IECEx and cETLus, with conformity to UL 61010-1, CAN/CSA-C22.2 No. 61010-1, EN 50270 and EN 61326-3-2.
Sensor options are OC-25, OC-25M, OC-26 and OC-26M, with process connections via KF-40 flange, KF-25 or 2-inch Tri-Clamp, and the OC-200 series for direct insertion. Please send the process gas composition, the oxygen range of interest, the process connection and the required alarm levels with your enquiry.
Identify the target gas, background gas and concentration units. State whether the sampling system is already installed or belongs in the enquiry.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.