Surent G480
Flow

Turbine & positive displacement meters
The SYS-FTBG-100 series is a gas turbine flowmeter system with an integrated transmitter in an ATEX explosion-proof enclosure. It measures the volumetric flow of non-corrosive gases such as natural gas, air, nitrogen and off-gas in pipelines and is used for fiscal measurement, plant cost allocation, monitoring of energy consumption or conservation, and custody transfer.
The gas flow spins a rotor that is supported by hybrid ceramic bearings for long service life. A magnetic pickup coil generates pulses at a frequency proportional to the flow rate. The microprocessor-based transmitter accepts frequencies from 0.2 to 4000 Hz and converts them into analogue and pulse outputs.
Stated accuracy is ±0.02 %, linearity ±1 % and repeatability ±0.25 % over the tabulated repeatable range; the temperature drift of the electronics is 40 ppm/°C. Meter sizes range from 1/4″ to 3″, and rotors with blade angles of 30° and 15° are available for different flow ranges.
The analogue output can be set by DIP switch to 4–20 mA or 1–5 V, with a 24 mA overflow condition. A pulse output is provided, and optional high and low alarms are available as relay (2 A, 30 V DC), 0–5 V or open collector (0.5 A, 30 V DC) outputs. An RS-232 interface is included. The standard supply is 13 to 30 V DC with reverse polarity protection; a 100 to 240 V AC supply is available with the -AC option. The electronics operate from −40 to 85 °C at 0 to 90 % RH non-condensing.
The meter body is 316/316L dual-rated stainless steel with a 17-4 PH rotor, and the transmitter sits in an aluminium enclosure rated IP66 / IP68. Process connections are NPT male, MS flared or flanged. The system carries ATEX approval and is CSA, CE, UKCA and RoHS compliant.
The meter must be installed horizontally, with at least 10 pipe diameters of straight run ahead of the inlet and 5 pipe diameters after the outlet.
Please send the gas, flow range, operating pressure and temperature, line size and the required outputs and power supply with your enquiry.
SYS/FTBG-101/FLSC-C3, SYS/FTBG-102/FLSC-C3, SYS/FTBG-103/FLSC-C3, SYS/FTBG-104/FLSC-C3, SYS/FTBG-105/FLSC-C3, SYS/FTBG-106/FLSC-C3, SYS/FTBG-107/FLSC-C3, SYS/FTBG-108/FLSC-C3, SYS/FTBG-109/FLSC-C3, SYS/FTBG-110/FLSC-C3, SYS/FTBG-111/FLSC-C3, SYS/FTBG-112/FLSC-C3, SYS/FTBG-113/FLSC-C3, SYS/FTBG-114/FLSC-C3, SYS/FTBG-115/FLSC-C3, SYS/FTBG-116/FLSC-C3, SYS/FTBG-101/FLSC-C3-AL, SYS/FTBG-102/FLSC-C3-AL, SYS/FTBG-103/FLSC-C3-AL, SYS/FTBG-104/FLSC-C3-AL, SYS/FTBG-105/FLSC-C3-AL, SYS/FTBG-106/FLSC-C3-AL, SYS/FTBG-107/FLSC-C3-AL, SYS/FTBG-108/FLSC-C3-AL, SYS/FTBG-109/FLSC-C3-AL, SYS/FTBG-110/FLSC-C3-AL, SYS/FTBG-111/FLSC-C3-AL, SYS/FTBG-112/FLSC-C3-AL, SYS/FTBG-113/FLSC-C3-AL, SYS/FTBG-114/FLSC-C3-AL, SYS/FTBG-115/FLSC-C3-AL, SYS/FTBG-116/FLSC-C3-AL, FLSC-C3, FLSC-C3-AL, OM-CONV-USB, FLSC-C-CABLE
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.