EDT 101
Temperature

Thermocouples
The T.4.-5 is a compact and robust stick-in temperature sensor with a thermocouple element and a straight cable outlet. It is designed for insertion into a protection tube at the measuring point and is intended for industrial and maritime use.
The sensor uses a type K (NiCr-Ni) or type J (Fe-CuNi) thermocouple. A thermocouple generates a small voltage that depends on the temperature difference between its measuring junction and the connected instrument, and this signal is evaluated by the downstream transmitter or controller. The measuring range of the T.4.-5 is 0 to 800 °C, and the sensor is made to tolerance class 1.
Standard immersion depths are 100, 150, 200 and 250 mm, with other lengths available on request. The sensor has a fixed connection cable, available in various lengths, that leaves the sensor in a straight line along its axis. This distinguishes it from versions of the same family with a 90° lateral outlet.
Both the sensor tube and the protection tube are made of stainless steel. The sensor itself has IP65 protection; when installed in a protection tube, IP68 is achieved.
The sensor carries BV, DNV and LR certificates, which supports its use in classified installations on ships.
The thermocouple type is designated K for NiCr-Ni and J for Fe-CuNi; both versions use the same stainless steel construction, the same immersion depths and the same protection degrees, and both cover the full measuring range from 0 to 800 °C.
The listed fields of application are shipbuilding, megayachts, transport technology, defence, machinery and equipment, and meteorology.
When ordering, the sensor is specified by the thermocouple type (K or J), the immersion depth, the cable length and, where required, the matching protection tube and the classification society certificate.
For a quotation, please send the thermocouple type, immersion depth, cable length, required certificate and the number of sensors.
Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.