DTL C
Electrical test & measurement

Current & voltage transducers
The T25CT is an open-loop Hall effect current transducer for the continuous conversion of DC and AC current into a DC voltage signal proportional to the measured value. It is designed for mounting directly on a busbar and accepts a cable or busbar through an aperture of 64 × 21 mm.
The measuring principle is the Hall effect. The current flowing in the conductor that passes through the aperture generates a magnetic field around it. In an open-loop transducer this field is concentrated onto a Hall element, in which an electrical voltage proportional to the field, and therefore to the current, is generated. The electronics amplify this voltage into the output signal. Because the conductor is not electrically connected to the transducer, the output signal is galvanically isolated from the measured circuit.
The transducer measures both direct and alternating current, and alternating current is represented as an RMS-proportional signal. Signals with frequencies up to 25 kHz can be measured. The output is an analogue voltage of ±4 V, whose value is proportional to the measured current.
The device is supplied with a bipolar voltage of ±15 V DC.
Mounting is simple: the transducer is placed directly on the busbar, and an accessory set is available for panel mounting or busbar mounting. The large rectangular aperture of 64 × 21 mm takes flat busbars as well as cables.
The transducer carries the UL Recognized Component Mark (UR) and is also listed for cUL; conformity with IEC requirements is stated.
The application named for the T25CT is the continuous conversion of DC and AC current into a DC voltage signal for current measurement, with the output galvanically isolated from the measured circuit.
When requesting an offer, please state the nominal current to be measured, the conductor dimensions, whether mounting accessories are needed, and the required quantity.
T25CT
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.