Socomec TF
Socomec

TF flexible current sensors 150–6000 A with RJ12 output

Current & voltage transducers

Manufacturer
Socomec
Model
TF
Instrument type
Current & voltage transducers
Sensor type
flexible current sensor
Measurement range
150 to 6000 A
Rated currents
400, 600, 2000, 4000, 6000 A
Openings
40, 80, 120, 200, 300, 600
Output
RJ12, plug-and-play
Compatible devices
DIRIS Digiware, DIRIS A-40, DIRIS B, ISOM Digiware F-60
References
48290573 to 48290578
Application
power quality monitoring and metering
Request a quote
Review enquiry

TF flexible current sensors measure load currents in electrical installations and transmit the measurement to power monitoring devices. They are used for power quality monitoring and metering, where currents on cables and busbars have to be recorded by a central measuring system.

The sensors are of flexible design. The output is a quick RJ12 plug-and-play connection to compatible meters. The sensors are intended for the DIRIS Digiware, DIRIS A-40, DIRIS B and ISOM Digiware F-60 ranges of power monitoring and insulation monitoring devices.

The series covers a wide measurement range of 150 to 6000 A. The sensors are offered with rated currents of 400, 600, 2000, 4000 and 6000 A and with openings of 40, 80, 120, 200, 300 and 600, so that the sensor size can be matched to the conductor or bundle of conductors to be measured.

The available references are as follows. 48290573 has an opening of 40 and a rated current of 400 A. 48290574 has an opening of 80 and a rated current of 600 A. 48290575 has an opening of 120 and a rated current of 2000 A. 48290576 has an opening of 200 and a rated current of 4000 A. 48290577 has an opening of 300 and a rated current of 6000 A, and 48290578 has an opening of 600 with a rated current of 6000 A. All references use the RJ12 secondary connection, and the series is listed with seven references in total.

Typical use is the measurement of load currents for power quality monitoring and energy metering in combination with the compatible measuring devices listed above.

When enquiring, please state the rated current, the required opening, the number of sensors and the measuring device with which they will be used.

Part numbers · 6

48290573, 48290574, 48290575, 48290576, 48290577, 48290578

Industry applications

Selection notes

Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU