Badger Meter UHC-120
Badger Meter

UHC-120 static ultrasonic thermal energy meter for heating and cooling

Water, gas & heat meters

Manufacturer
Badger Meter
Model
UHC-120
Instrument type
Water, gas & heat meters
Measured quantity
heating and/or cooling energy
Measuring principle
ultrasonic flow measurement with temperature sensors, static
Sizes
15–40 mm (½–1-1/2 in)
Flow range
1.5–20 m³/h (6.6–88 gpm)
Temperature range
5 to 90 °C
Pressure
up to 16 bar (232 psi)
Accuracy
class 2 approvals
Communication
modular; Modbus RTU
Power supply
battery, 24 V AC or 230 V AC
Approvals
MID; EN 1434; Measurement Canada
Request a quote
Review enquiry

The UHC-120 is a static ultrasonic thermal energy meter for measuring consumed heating and/or cooling energy. It is designed for multi-family residences and for commercial and mixed-use buildings, and is used in HVAC systems and property operations.

The meter combines high-precision temperature sensors with ultrasonic flow measurement. The flow of the heat transfer liquid is measured ultrasonically, and the temperature sensors measure the temperatures of the flow and return lines; from flow and temperature difference the meter calculates the thermal energy. As a static meter it has no moving parts subject to wear, which supports long-duration reliability.

The UHC-120 is available in sizes from 15 to 40 mm (½ to 1-1/2 inches), with a flow range of 1.5 to 20 m³/h (6.6 to 88 gpm). It operates at liquid temperatures from 5 to 90 °C and pressures up to 16 bar (232 psi). The meter holds class 2 accuracy approvals.

The compact design allows installation in small spaces. Communication options are modular, and Modbus RTU communication is available. Power can be supplied by battery, or by 24 V AC or 230 V AC, depending on the option selected.

The meter complies with the Measuring Instruments Directive (MID) and EN 1434 and has Measurement Canada approval.

Options are the power supply (battery, 24 V AC or 230 V AC) and Modbus RTU communication, together with the size from 15 to 40 mm. The main features are class 2 accuracy approvals, modular communication, a compact design, no moving parts and long-duration reliability.

Typical applications are heating and cooling energy metering in multi-family residences, commercial and mixed-use buildings, HVAC systems and property operations. Please state the size, flow range, whether heating, cooling or both are to be measured, the power supply and the communication required in your enquiry.

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments