Type 8189
Level

Capacitive level sensors
The ULS-200 is a single-point capacitance level sensor designed for OEM applications. It detects aqueous, oil and hydrocarbon liquids, is less than 3.25 in long and is built to work in harsh environments. The sensor resists coating and build-up on the probe.
The sensor works on the capacitance principle and switches with a solid-state circuit, so it has no moving parts. It is factory-set to trigger on wet or dry conditions. Optional time delays of 3, 5 or 10 seconds, selectable separately for increasing and decreasing level, prevent false switching caused by sloshing or turbulence. The sensor can be installed in any orientation.
The supply voltage range is 9 to 32 V DC, and current consumption without load is 6 mA maximum. The solid-state output switches up to 300 mA at supply voltage and is available in sinking or sourcing versions, with actuation set as wet source, dry source, wet sink or dry sink. Electrical connection is made through an integral DT04-3P connector.
The sensor withstands process pressure up to 300 psi and temperatures up to 257 °F. Housings are made of brass or 316 stainless steel, and the probe of PBT or PVDF. Mounting threads include 1/2" NPT, 1/4" NPT, G1/4-19 and M12 × 1.5. Ingress protection is IPX7 and IP6K9K, and the sensor carries CE and RoHS markings.
Configuration options therefore cover the housing material, probe material, mounting thread, sensed medium (water, oil or hydrocarbon), switch action and time delays.
Application areas given for the ULS-200 include agricultural and construction equipment, buses, power generation, semiconductor equipment and HVAC. When you enquire, please state the liquid to be detected, wet or dry switching, sinking or sourcing output, the required time delays, the mounting thread and the housing and probe materials.
ULS-200
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.