Heinrichs Messtechnik UMF2
Heinrichs Messtechnik

UMF2 transmitter for electromagnetic flow sensors

Electromagnetic flowmeters

Manufacturer
Heinrichs Messtechnik
Model
UMF2
Instrument type
Electromagnetic flowmeters
Function
transmitter for electromagnetic flow sensors
Compatible sensors
EPS, PIT, PITe, PITY series
Flow velocity range
0.1 to 10 m/s
Accuracy
0.5 % of reading
Minimum conductivity
> 5 µS/cm
Analogue output
1 × 0/4–20 mA active, galvanically isolated
Pulse output
passive, isolated, max. 30 V, 60 mA, 1.8 W, up to 1 kHz, 0.1–2000 ms
Status output
passive, isolated, max. 30 V, 60 mA
Communication
HART (option), RS-485
Counters
2 flow counters, 1 reflux counter
Power supply
115/230 V AC 50/60 Hz, 10 VA; 24 V DC, 10 W
Ambient temperature
−20 to +60 °C
Housing
coated die-cast aluminium
Protection
IP67; IP68 on request; NEMA 6P
Mounting
compact (integral) or remote; pipe or wall
Request a quote
Review enquiry

The UMF2 is a digital, microprocessor-controlled transmitter for electromagnetic flow sensors of the EPS, PIT, PITe and PITY series. Together with the sensor it measures the volume flow of electrically conductive liquids, totalises the volume and also provides density monitoring.

The measurement is based on Faraday's law of electromagnetic induction. The transmitter generates the coil current that produces the magnetic field in the sensor and preprocesses the voltage induced at the electrodes, which is proportional to the flow velocity. From this signal it calculates flow velocity, volume flow and density, and it can also display and transmit temperature.

The flow velocity range is 0.1 to 10 m/s and accuracy is 0.5 % of reading. The liquid must have a conductivity above 5 µS/cm. Two flow counters and one reflux counter are provided. The electronics are interchangeable without recalibration, and the configuration is stored on a replaceable data memory chip (DSM). A self-monitoring system and diagnostic functions are built in, including empty pipe detection with the BE3 control unit.

Outputs are galvanically isolated: one active 0/4–20 mA analogue output, a passive pulse output and a passive status output. The pulse output is rated 30 V, 60 mA and 1.8 W, with a maximum frequency of 1 kHz and a pulse duration from 0.1 to 2000 ms. HART communication is available as an option, and RS-485 is listed. The transmitter is supplied with 115/230 V AC at 50/60 Hz (10 VA) or 24 V DC (10 W).

The housing is coated die-cast aluminium, rated IP67 to EN 60529, with IP68 on request; NEMA 6P is also listed. The ambient temperature range is −20 to +60 °C. The transmitter can be mounted integrally on the sensor as a compact version, or separately on a vertical pipe or wall.

Options include the BE3 control unit with backlit LCD, HART, IP68, remote or integral installation, an explosion-proof version and an outdoor version. Installation and servicing must be carried out by qualified personnel, with equipotential bonding between sensor and transmitter and suitable cable glands. Please send the sensor type and size, the medium, the flow range and the required outputs with your enquiry.

Part numbers · 1

UMF2

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.