Type 8203
Liquid analysis

Water quality analysers
The UV500 IMO is a compact online water quality analyser for monitoring the washwater of exhaust gas cleaning systems (scrubbers) on ships. It measures the parameters required by the IMO discharge criteria of MEPC 259(68): polycyclic aromatic hydrocarbons (PAH), pH, turbidity and temperature, and is suitable for open-loop, closed-loop and hybrid scrubbers.
PAH are measured by a UV-fluorescence module with a xenon flash lamp. Turbidity is measured by nephelometry with an infrared laser diode, in accordance with ISO 7027. Internal probes measure pH and temperature. An automatic cleaning system using 5 % sulphuric acid prevents clogging and drift of the measuring cells.
Ranges are 0–1000 µg/l for PAH, 0–14 for pH, 0–100 NTU or 0–1000 NTU for turbidity and 0–80 °C for temperature. A measurement takes five seconds. The sample is supplied at 0–5 l/min, 0–4 bar and 0–80 °C, and the analyser works with pressurised or unpressurised sampling systems. Media named are sea water, washwater, process water and wastewater.
Results are shown on a 10.4-inch colour touch screen. Modbus communication is available via RS-232 and RS-485, together with USB. Options include 4–20 mA output modules, Wi-Fi (IEEE 802.11b), Ethernet (IEEE 802.3), a built-in peristaltic sampling pump and a multiplexing system for measuring several streams, for example scrubber inlet and outlet, with one analyser. Power supply is 90–264 V AC, 50–60 Hz, with a maximum of 100 VA.
The analyser is housed in an IP65 stainless steel enclosure measuring 360 × 420 × 229 mm (H × L × D) and weighs 23 kg; wall mounting brackets are included. Wetted materials are quartz, polypropylene, polyethylene, FPM (Viton) and PMMA. The unit carries DNV, LR and BV class approvals and the CE marking, and conforms to EN 61010-1 and EN 61326.
Applications are washwater monitoring of marine exhaust gas cleaning systems, monitoring of scrubber inlet and outlet, sea water discharge monitoring and industrial wastewater analysis.
Please state the scrubber type, the number of streams to be monitored, the turbidity range and the required outputs.
UV500 IMO
Record the sample temperature, expected concentration and how the probe is mounted. Identify the mating transmitter when replacing a sensor.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.