PACE6000-ADC
Calibration

Multifunction process calibrators
The VA700 is a handheld loop calibrator for work on industrial signal loops. It serves both as a signal source and as a measuring instrument, so one compact device is enough to check the two most common analogue signals in process instrumentation: DC current up to 24 mA and DC voltage up to 20 V.
In current mode the calibrator measures or outputs a DC current from 0 to 24 mA. This covers the standard 4–20 mA range together with the values just below and above it, which are used to check how transmitters, controllers, indicators and control system inputs behave at the ends of the range. In voltage mode it measures or outputs DC voltage from 0 to 20 V, suitable for 0–10 V and similar voltage signals. The calibrator works either as a source or as a meter; it does not measure and source at the same time.
The temperature coefficient is ±0.005 % of range per °C. The instrument operates from −10 to 55 °C at altitudes up to 3000 m and can be stored from −40 to 60 °C. Permitted relative humidity is 95 % up to 30 °C, 75 % up to 40 °C, 45 % up to 50 °C and 35 % up to 55 °C. The maximum voltage between any jack and earth is 30 V, and the device is tested for random shock of 2 g from 5 to 500 Hz.
The calibrator is powered by six AAA batteries, so it can be used anywhere in a plant without a mains supply. It measures 204 × 99 × 46 mm, weighs 460 g and is CE marked.
Typical tasks are checking and adjusting the current and voltage loops of transmitters, controllers and panel indicators during commissioning and maintenance. Contact us for a quotation and let us know which signals you need to source or measure.
VA700
Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.