Surent G480
Flow

Ultrasonic flowmeters
The XFT Series is a clamp-on ultrasonic flow meter for non-invasive measurement of liquid flow and temperature. It is fitted on the outside of the pipe, so it needs neither pipe cutting nor reducer unions, and it can be installed without shutting the system down. With no parts in the flow, it causes no pressure loss and has no moving parts.
The meter uses ultrasonic sensors that transmit signals through the pipe wall into the liquid. It is designed for compatible pipe materials, namely stainless steel, PVC and PPR. Models are available for nominal pipe sizes of 3/8 in (16–18 mm OD), 1/2 in (18–23 mm OD), 3/4 in (23–28 mm OD), 1 in (28–37 mm OD), 1-1/4 in (37–44 mm OD) and 1-1/2 in (44–52 mm OD).
The maximum flow rate is 105.7 GPM. Standard flow accuracy is typically ±2 % of full scale, with a maximum of ±3 % of full scale. Operating temperature is 14 to 140 °F (−10 to 60 °C). Media named include various cooling liquids, deionised water and oil substances.
Measured values are shown on a full-colour LCD that can be rotated to suit the mounting position. For connection to control systems, the meter provides a 4–20 mA analogue output and RS485 with Modbus RTU communication, both with short-circuit protection. The electrical termination is an M12 A-coded 8-pin male connector; M12 cables are available in lengths of 2, 4, 6 and 8 m (for example M12-8A-002).
The body is made of plastic and rated IP66. The meter carries the CE mark and complies with REACH and RoHS. Multiple model configurations are offered, such as XFTDEBL100, XFTDJBL100 and XFTDFBL100, corresponding to pipe size and version.
Applications named are general automation machine cooling, industrial chiller flow monitoring, liquid-cooled servers and coolant distribution units, semiconductor process equipment and cooling of microwave and RF power supplies. Please state the pipe size and material, the liquid and the cable length in your enquiry.
XFTDEBL100, XFTDJBL100, XFTDFBL100, XFTDJAL100, XFTDFAL100, XFTDFCL100, M12-8A-002, XFTDGBL100, XFTDDBL100, XFTDHCL100, XFTDDAL100, XFTDJCL100, XFTDGAL100, XFTDECL100, XFTDGCL100, XFTDHAL100, XFTDEAL100, XFTDDCL100, XFTDHBL100, M12-8A-006, M12-8A-004
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.