Type 8189
Level

Float & magnetic level indicators
The XM-800 Series is a compact continuous float level transmitter for remote tank gauging in small to mid-size process tanks. It is built in rugged 316 stainless steel or brass and provides a dependable analogue output with 1/4 in (6 mm) resolution. The series is used in process and OEM applications, and OEM configurations are available.
A float moves along a stem of brass or 316 stainless steel with the liquid level, and the transmitter converts its position into a continuous analogue signal. The output can be shown on digital bargraph displays and level receivers for local or remote monitoring. The XM-800 provides the standard outputs, while the XT-800 version allows various signal conditioning options.
Overall length reaches up to 144 in (366 cm), with an indication range of up to 141 in. The transmitter operates from −40 to 110 °C (−40 to 230 °F) and at pressures up to 300 PSI (21 bar).
Output signals are a proportional voltage of 0–5 VDC or 0–12 VDC, or 4–20 mA. The XM-800 delivers the voltage output or a stem-mounted 4–20 mA output. The XT-800 can be equipped with a stem-mounted or a junction-box signal conditioner for 0–5/12 VDC or 4–20 mA, or with a panel-mount conditioner on a plug-in base. Electrical termination is by two or three 22 AWG lead wires, 24 in (60.9 cm) long with PTFE jacket, or by a junction box; a NEMA 4 junction box is available, and enclosure types 1, 2, 3, 4, 6 and 10 are listed.
Mounting types include 1/2-14 NPT, 1-11.5 NPT, 1 1/4 NPT and 2-11.5 NPT threads, a 3 in 150# flange and a 2 1/2 in sanitary flange. The transmitter weighs approximately 10 lb (4.5 kg) and is UL recognised and CSA certified.
Configured versions are identified by part numbers such as W1083495, W122311 or W54176.
When enquiring, please state the tank height or required length, stem material, mounting type, process pressure and temperature, output signal and whether signal conditioning in a junction box or panel mount is required.
W1083495, W122311, W1099667, W1086992, W124595, W54176, W1111504, W1095729, W1099874, W1099306, W1047742, W1110087, W1112196, W404523, W1026449, WEB0051307, W1115727, W1113062, W1026451, W1113732, W1035613, W1083237, W1082246, W1086129, W1069517
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.