Type 8189
Level

Float & magnetic level indicators
The XM-XT 700 Series is a compact continuous float level transmitter that combines the durability of stainless steel or brass construction with a lightweight design for restricted spaces. It is intended for shallow tanks and reservoirs less than 2 ft deep and for OEM applications.
A float moves along the stem with the liquid level and provides a continuous level signal with a resolution of 4 mm. Output types available for the series are proportional voltage, 4–20 mA, 0–5 VDC and 0–10 VDC. The indicating length extends to 14 in (35.5 cm) and the stem length to 20 in (508 mm); custom lengths are available on request.
Stems and mountings are made of brass or 316 stainless steel. Float options include polypropylene in hollow (259125), foamed (119455) and moulded (231500) versions, Buna N (245900), polysulfone (39005) and 316/316L stainless steel (258260), so the float can be chosen to suit the liquid. The maximum pressure rating is 50 psi (3.45 bar) and the operating temperature range −40 to 150 °F. The transmitter is mounted vertically, with an inclination of up to ±30° permitted.
Mounting types include 1/8-27 NPT, 3/4-14 NPT and 1 1/4-11.5 NPT threads, 3/8-24 UNF-2A and 15/16-12 UNF-2A threads and a Ø 3 5/8 in flange. A 1/2 in MNPT conduit adapter is optional, and sanitary flange mountings are available on request. The enclosure is NEMA 4 and Type 6P encapsulated, corrosion-resistant and submersible. The transmitter is not intrinsically safe.
The data listed for the series also cover a plug-in control module with an 11-pin octal socket and screw terminals, 120 VAC supply, direct mode of operation, one normally open non-powered contact rated 10 A resistive or 1/3 hp, and sensitivity settings of 4.7 kΩ, 26 kΩ or 100 kΩ.
Configured versions are identified by part numbers such as 257830, 259587 or 263379.
Typical applications named are shallow tanks, reservoirs and OEM equipment with limited mounting space.
When enquiring, please state the tank depth or stem length, stem material, float material, mounting type, output signal and the liquid to be measured.
257830, 259587, 263379, 257915, 258561, 261012, 259405, 262646, 263662, 264467, 262988, 264104, 259319, 260707, 258253, 262191, 264603, 256121, 264582, 257921, 261462, 261290, 254380, 259724, 256682, 259125, 119455, 231500, 245900, 39005, 258260
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.