HORIBA 3574-10C
HORIBA

3574-10C flow-type conductivity cell for small sample volumes, K = 10 cm⁻¹

Conductivity & resistivity sensors

Manufacturer
HORIBA
Model
3574-10C
Instrument type
Conductivity & resistivity sensors
Type
flow-type conductivity cell
Cell constant
10 cm⁻¹
Measuring range
10 µS/cm to 100 mS/cm
Sample volume required
0.25 ml
Temperature range
0 to 80 °C
Electrodes
platinum, coated with platinum black
Body
glass
Connector
BNC
Cable length
1 m
Dimensions
length 136 mm, diameter 66 mm
Compliance
RoHS (EN IEC 63000)
Request a quote
Review enquiry

The 3574-10C is a flow-type conductivity cell for measuring electrical conductivity in small sample volumes. Instead of being immersed in a beaker, the cell is connected so that the sample flows through it, and it requires only 0.25 ml of sample. This makes it suitable for applications such as column chromatography, where only a very small amount of sample is available.

The cell has a cell constant of 10 cm⁻¹ and a measuring range of 10 µS/cm to 100 mS/cm. The electrodes are made of platinum coated with platinum black and are housed in a glass body. The cell is used at temperatures from 0 to 80 °C.

The cell is connected to the meter through a BNC connector on a 1-metre cable. It is 136 mm long and 66 mm in diameter. The product complies with RoHS requirements according to EN IEC 63000 and BS EN IEC 63000.

As a flow-type cell, the 3574-10C is designed for measuring very small quantities of liquid as they pass through the cell, rather than for immersion in a larger sample; a submersible design is listed as an alternative option.

The flow-through design means that the sample does not have to be collected in a separate vessel before measurement: the liquid leaving, for example, a chromatography column can be passed straight through the cell and its conductivity read on the connected meter.

The listed fields of use are column chromatography with very small sample amounts, water quality measurement and scientific work.

When selecting a cell, the sample volume and the conductivity range are the main criteria. With its small internal volume and its range from 10 µS/cm to 100 mS/cm, the 3574-10C covers small samples of moderate to high conductivity.

To request a quotation, please state the quantity and the meter to which the cell will be connected.

Part numbers · 1

3574-10C

Industry applications

Selection notes

Record the sample temperature, expected concentration and how the probe is mounted. Identify the mating transmitter when replacing a sensor.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments