Current & voltage transducers
These DC shunt resistors provide an accurate millivolt signal proportional to a direct current in the higher ampere ranges. They are used to drive moving-coil ammeters, overload protection devices and control units, which cannot carry the full load current themselves but measure the small voltage drop across the shunt.
The shunt is a precisely calibrated low-value resistor through which the primary current flows. A current from 10 A up to 1500 A, depending on the rating, produces a secondary voltage of 60 mV at the measuring terminals. Accuracy is class 0.5, calibrated at 75 % of the nominal current In. The temperature coefficient is 0.05 % per 10 °C, and the shunts operate in a temperature range of −10 to 55 °C. The shunts are designed to IEC/EN 60051-1.
The 60 mV signal is suitable for moving-coil ammeters with 90° or 240° pointer deflection, which can be supplied with customised and exchangeable scales, so the indicator shows the current in amperes directly. The same signal can also be connected to overload protection relays or control units that accept a 60 mV shunt input.
Dimensions comply with DIN 43703. The shunts are available in form A and form B variants, with or without a base, and are protected to IP52, with IP54 on request. When installing, the specified tightening torque for the copper-to-copper connections must be observed, since the contact resistance of these connections affects the measurement.
Stated fields of use are marine and offshore, power generation, hybrid power, grid connection, data centres, hospitals, telecom, airports, infrastructure and fish farms.
Ratings are selected along the 10 to 1500 A range so that the nominal current of the circuit corresponds to the 60 mV output. Please send the nominal current, the required form and whether a base is needed, together with details of the ammeter or control unit that the shunt will supply.
4921210042I
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.