DwyerOmega ISE8700 / ISE8800 / ISE8900
DwyerOmega

ISE8700 / ISE8800 / ISE8900 ion selective electrodes

Water quality analysers

Manufacturer
DwyerOmega
Model
ISE8700 / ISE8800 / ISE8900
Instrument type
Water quality analysers
Measured ions
ammonia, chloride, copper, fluoride, lead, nitrate, potassium, sodium, water hardness
Sensor types
gas-sensing combination, polymer membrane mono, solid-state mono, combination
Measuring range
0.01 to 17000 ppm (direct measurement)
Sensitivity
up to 57 mV per decade
Response time
20 or 30 s
Process temperature
0 to 80 °C
Housing materials
epoxy, PVC, glass
Reference electrodes
PHE-3211 double junction, PHE-3111 single junction
Shelf life
16 months
Approvals
RoHS
Request a quote
Review enquiry

The ISE8700, ISE8800 and ISE8900 series are ion selective electrodes (ISE) for measuring the concentration of specific ions in aqueous solutions. Electrodes are available for ammonia, chloride, copper, fluoride, lead, nitrate, potassium, sodium and water hardness, which lets one measuring approach cover many routine analyses in water and process samples.

An ion selective electrode carries a sensing membrane that responds to one type of ion. In contact with the sample, a potential develops across the membrane that changes with the logarithm of the ion concentration; it is measured against a reference electrode, and the meter converts the millivolt signal to concentration. The sensitivity of these electrodes is as high as 57 mV per decade of concentration.

Four sensor technologies are used, depending on the ion: gas-sensing combination electrodes, polymer membrane mono electrodes, solid-state mono electrodes and combination electrodes. Mono electrodes are used together with a separate reference electrode; for this purpose, a double junction reference electrode PHE-3211 and a single junction reference electrode PHE-3111 are offered. Combination electrodes contain the reference in the same body.

Direct measurement ranges extend from 0.01 to 17000 ppm, or the corresponding molar values, depending on the ion. Response times are 20 or 30 seconds. The electrodes operate at process temperatures from 0 to 80 °C. Housings are made of epoxy, PVC or glass, according to the electrode type. Shelf life is 16 months, and the products are RoHS compliant.

For reliable results, matching solutions are available: standard solutions for calibration, ionic strength adjuster (ISA) solutions that are added to samples and standards, and reference outer-fill solutions for the reference electrodes.

Typical applications are industrial water analysis, wastewater treatment, environmental monitoring and chemical process control. Please tell us which ion you need to measure, the expected concentration range and the meter you will use, and we will select the electrode, reference electrode and solutions.

Part numbers · 54

ISE-8710, ISE-8711, ISE-8712, ISE-8720, ISE-8722, ISE-8730, ISE-8732, ISE-8740, ISE-8742, ISE-8750, ISE-8760, ISE-8770, ISE-8800, ISE-8802, ISE-8780, ISE-8782, ISE-8790, ISE-8795, ISE-8810, ISE-8812, ISE-8715, ISE-8716, ISE-8725, ISE-8726, ISE-8735, ISE-8736, ISE-8830, ISE-8840, ISE-8842, ISE-8745, ISE-8746, ISE-8755, ISE-8756, ISE-8765, ISE-8860, ISE-8880, ISE-8882, ISE-8900, ISE-8902, PHFS-8710, PHFS-1042, PHFS-1043, PHFS-NO3, PHFS-4MKCL, PHFS-8750, PHFS-1046, PHFS-1045, PHFS-1044, PHFS-KCL, PHFS-NOX, PHFS-1041, PHFS-1047, PHE-3211, PHE-3111

Industry applications

Selection notes

Record the sample temperature, expected concentration and how the probe is mounted. Identify the mating transmitter when replacing a sensor.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU