LUMEL NMID33
LUMEL

NMID33 three-phase MID energy meter up to 100 A with Modbus RTU

Energy meters

Manufacturer
LUMEL
Model
NMID33
Instrument type
Energy meters
Network
3-phase 4-wire, 3-phase 3-wire, 1-phase 2-wire
Current measurement
Direct, up to 100 A
Measurement
True RMS, bidirectional (imported/exported)
Accuracy class
B (EN 50470-3), class 1 (IEC 62053-21)
Standards
EN 50470-3, IEC 62053-21, IEC 62053-23
Power supply
Self-powered from the measuring circuit
Display
1-line, 8-digit seven-segment LCD
Tariffs
Up to four
Communication
RS-485, Modbus RTU
Pulse outputs
Two S0
Digital inputs
Two
Housing
4 modules (72 mm), DIN rail
Terminals
Sealable
Approvals
MID, CE
Request a quote
Review enquiry

The NMID33 is a three-phase digital electricity meter for residential buildings, commercial facilities and light industry. It is MID certified and can be connected to 3-phase 4-wire, 3-phase 3-wire and 1-phase 2-wire systems,

Current is measured directly up to 100 A, without external current transformers, and the meter is powered from the measuring circuit itself, so no separate auxiliary supply is needed. Measurement is True RMS. The meter records energy in both directions, imported and exported. Readings are shown on a one-line, 8-digit seven-segment LCD, and energy consumption is indicated by a pulse LED.

The accuracy is class B according to EN 50470-3 and class 1 according to IEC 62053-21; reactive energy is covered by IEC 62053-23. Up to four energy tariffs are available. The active tariff can be selected via the two digital inputs or remotely through the RS-485 interface.

For integration into building management, energy monitoring or billing systems, the meter has an RS-485 port with the Modbus RTU protocol. In addition, two S0 pulse outputs are provided for connection to pulse counters or data loggers. The terminals can be sealed to prevent unauthorised access after installation.

The housing is 4 modules (72 mm) wide and is mounted on a standard DIN rail in distribution boards. The device carries the MID certificate and a CE declaration of conformity.

Related versions of the same meter are available: the NMID33MBUS uses the M-Bus protocol instead of Modbus RTU, and the NMID33LITE is a version without the communication interface.

Typical applications named for the meter are sub-metering and energy measurement in residential buildings, commercial facilities and light industrial installations.

Please include the required version (Modbus RTU, M-Bus or Lite), the network type and the quantity in your enquiry.

Part numbers · 1

NMID33

Industry applications

Selection notes

Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments