DTL C
Electrical test & measurement

Energy meters
NR10PLUS is a single-phase digital multifunction meter for energy measurement and monitoring of power parameters in single-phase networks. It is designed for direct connection up to 100 A, so no current transformers are required, and it is mounted on a standard 35 mm DIN rail in distribution boards.
The meter is microprocessor-based. It measures the phase-to-neutral voltage, frequency and current and calculates active power (kW), apparent power (kVA), reactive power (kvar) and power factor. Maximum demand values are recorded for current, active power and apparent power, which helps to see the highest loads that occurred in a period.
Energy is measured bidirectionally. Separate registers count imported and exported active energy (kWh) and imported and exported reactive energy (kvarh), and totals are provided for active, reactive and apparent energy. This makes the meter suitable for installations where energy can flow in both directions. Two tariff counters allow consumption to be divided between two tariff periods. The accuracy for active energy corresponds to class B according to EN 50470-3.
For connection to other systems the meter has two pulse outputs, which can transmit energy pulses to a counter, controller or data logger, and a digital input. Data communication is via an RS-485 interface with the Modbus RTU protocol, so all measured values and energy registers can be read by a building management system or a remote monitoring system. Readings are shown locally on a blue backlit display.
Installation is made on a 35 mm DIN rail. With direct connection up to 100 A and compact rail mounting, the meter is installed directly in the single-phase circuit to be measured.
Listed applications are single-phase network monitoring, building management systems (BMS) and remote monitoring systems, where energy data has to be collected and transmitted over Modbus. The product is supplied as the base version NR10PLUS.
Please state the quantity and whether the meter will be integrated via Modbus RTU or pulse outputs, so that we can confirm the configuration in our quotation.
NR10PLUS
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.