Current & voltage transducers
The P43 is a transducer of power network parameters for three-phase, 3-wire or 4-wire networks in balanced or unbalanced systems. It measures the network quantities and converts them into analogue signals, relay alarms, energy pulses and digital data. The unit is rail mounted and measures 90 × 120 × 100 mm.
Voltage inputs are programmable for 100 V or 400 V, and current inputs for 1 A or 5 A. Current can also be measured with current transformers that have an x/333 mV output. The ratios of the current and voltage transformers are programmable. Inputs and outputs are galvanically isolated. The x/333 mV input allows current transformers with a low-voltage output to be used instead of transformers with a conventional 1 A or 5 A secondary current. Because unbalanced systems are covered, phases with different loads are measured individually.
Three output configurations are available: four relays for signalling when measured quantities exceed set limits, without analogue outputs; two relays and two analogue outputs; or four analogue outputs without relays. In addition, a pulse output provides a signal proportional to the three-phase active energy consumption.
The transducer has a built-in memory for the 15-minute power profile and stores the maximum and minimum values of the measured quantities. Communication with higher-level systems uses RS-485 and USB interfaces with the Modbus protocol. Programming is carried out with free configuration software.
The listed application is the conversion of three-phase, 3-wire or 4-wire power network parameters in balanced or unbalanced systems.
When requesting a quotation, please state the nominal voltage, the current input type (1 A, 5 A or x/333 mV transformers), the required output configuration, whether the pulse output is needed and the number of units.
P43
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.