SENECA T201DCH600-MU
SENECA

T201DCH600-MU ±600 A AC/DC Hall-effect current transducer with Modbus

Current & voltage transducers

Manufacturer
SENECA
Model
T201DCH600-MU
Instrument type
Current & voltage transducers
Input
AC/DC −600 to +600 A; ranges 0–300 A, 0–600 A, ±300 A, ±600 A
Measurement type
AC/DC TRMS or bipolar DC, Hall effect
Accuracy class
0.5
Resolution
13 bit (10000 points)
Pass band
1 kHz; crest factor 2
Overload
2000 A impulsive; 3 × In continuous
Outputs
1 AO 0–10 V; 1 DO alarm contact
Interfaces
RS485 Modbus RTU; micro USB
Configuration
DIP switches or setup software
Power supply
12–28 V DC, typical 21 mA
Insulation voltage
3 kV AC
Overvoltage category
CAT III 300 V (bare conductor); CAT III 600 V (insulated conductor)
Housing
PA6, black, IP20, 35 mm DIN rail
Dimensions
75 × 95 × 35 mm, hole Ø 35 mm
Operating temperature
−25 to +70 °C
Request a quote
Review enquiry

The T201DCH600-MU is an isolated current transducer for measuring AC and DC currents up to ±600 A without contact with the circuit. The cable is passed through the central hole of the housing, and a Hall-effect sensor converts the current into an analogue output signal and digital data. The device is used as a signal converter for current measurement in industrial automation, power monitoring and HVAC systems.

Two measuring modes are available: AC/DC TRMS, which gives the true RMS value of alternating, direct or mixed currents, and bipolar DC, which follows the sign of a direct current. Input ranges of 0–300 A, 0–600 A, −300 to +300 A and −600 to +600 A can be selected. The pass band is 1 kHz with a crest factor of 2, and the transducer withstands 2000 A impulsive overload and three times the rated current continuously.

The accuracy class is 0.5. Above 2 % of full scale the error is 0.5 % of full scale, below 2 % of full scale it is 1 % of full scale at 50/60 Hz and 23 °C. Resolution is 13 bit (10000 points), the temperature coefficient below 200 ppm/°C, hysteresis 0.2 % of full scale and EMI error below 0.5 %. A selectable filter sets the response speed: in RMS mode 1400 ms (fast) or 2900 ms (slow), in bipolar mode 78 ms (fast) or 650 ms (slow).

The analogue output supplies 0–10 V with 13-bit resolution, and a digital output acts as an alarm contact with configurable alarm types and thresholds. Measured values are also available over RS485 with the Modbus RTU protocol. Configuration is done with DIP switches or with the setup software through the micro USB port. The transducer is powered with 12–28 V DC and draws typically 21 mA; insulation voltage is 3 kV AC.

The black PA6 housing measures 75 × 95 × 35 mm with a 35 mm hole, is rated IP20 and mounts on a 35 mm DIN rail to IEC EN 60715. Connections are made with removable 6-way screw terminals at 5 mm pitch for cables up to 2.5 mm². The overvoltage category is CAT III 300 V for bare conductors and CAT III 600 V for insulated conductors. Operating temperature is −25 to +70 °C at 10–90 % humidity without condensation, storage temperature −40 to +85 °C, and the device can be used up to 2000 m with bare and 3500 m with insulated conductors. It complies with the EMC and Low Voltage Directives, RoHS and REACH and with EN 61010-1.

Other versions of the series cover ±50 A, ±100 A and ±300 A (T201DCH50-MU, T201DCH100-MU, T201DCH300-MU), and openable versions are offered for 100, 300 and 600 A (T201DCH100-OPEN, T201DCH300-OPEN, T201DCH600-OPEN). Please state the current range, type of current and whether an openable version is required in your enquiry.

Part numbers · 1

T201DCH600-MU

Industry applications

Selection notes

Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU