LUMEL VA311B
LUMEL

VA311B true-RMS AC/DC clamp meter, 1000 A

Multimeters & clamp meters

Manufacturer
LUMEL
Model
VA311B
Instrument type
Multimeters & clamp meters
Display
3¾ digits, 3999 counts
AC/DC current
400.0 A and 1000 A ranges
AC/DC voltage
up to 1000 V
AC voltage bandwidth
40 Hz to 1000 Hz
AC current bandwidth
40 Hz to 400 Hz
Resistance
up to 40 MΩ
Continuity
beeper at ≤ 50 Ω
Capacitance
up to 4 mF
Frequency
up to 4 MHz (logic); up to 100 kHz (linear)
Temperature
−200 °C to 1200 °C
Jaw opening
max. 42 mm
Measurement
true RMS
Other functions
non-contact voltage detection (NCV/EF)
Request a quote
Review enquiry

VA311B is a 3¾-digit, 3999-count true-RMS digital clamp meter for non-intrusive measurement of AC and DC currents up to 1000 A. The current is measured with the clamp jaws around a conductor, so the circuit does not have to be opened, while voltage, resistance, capacitance, frequency and temperature are measured through the input terminals.

Current is measured in two ranges, 400.0 A and 1000 A, for both AC and DC. The 400.0 A range resolves currents to 0.1 A, while the 1000 A range covers higher loads. The jaw opening is up to 42 mm, which determines the largest conductor or bundle that can be enclosed. Because AC values are measured as true RMS, readings remain correct when the waveform is not sinusoidal; the AC voltage bandwidth is 40 Hz to 1000 Hz and the AC current bandwidth 40 Hz to 400 Hz.

AC and DC voltage are measured up to 1000 V. Resistance is measured up to 40 MΩ, and continuity is indicated at a resistance of 50 Ω or less. Capacitance ranges extend up to 4 mF. Frequency is measured up to 4 MHz as a logic signal and up to 100 kHz as a linear signal. With a suitable probe, the meter measures temperature from −200 °C to 1200 °C.

A non-contact voltage detection function (NCV/EF) indicates the presence of AC voltage near a conductor without electrical contact, which helps to identify live cables before work starts. The meter carries CAT II and CAT III safety ratings.

Stated applications for the meter are power engineering, photovoltaic installations, electric vehicles, automotive applications and industrial automation.

All these functions are combined in one handheld instrument, so current at the conductor and voltage, resistance or temperature at the terminals can be checked with the same meter. Please let us know the quantity required and whether test leads or a temperature probe should be quoted together with the clamp meter.

Part numbers · 1

VA311B

Industry applications

Selection notes

Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.