Electrical test & measurement

Energy meters
WQR96 MKII is a family of microprocessor-controlled kWh counters for switchboard mounting. They measure imported or exported energy in single-phase and three-phase networks and are widely used in generator and distribution switchboards, where a simple, permanently readable energy register is required.
The energy is shown on a seven-digit electromechanical counter. Unlike an electronic display, the counter keeps its reading even if the supply voltage fails, so the accumulated energy is never lost. Measurement accuracy is class 1 for active energy according to EN 62053-21 and class 2 for reactive energy according to EN 62053-23. The meters connect to current transformers with 1 A or 5 A secondary current, with a measuring range up to 1.6 times nominal current, and to voltages of up to 400 V phase to neutral or 690 V between phases. The measuring frequency range of 16 to 400 Hz covers generator sets and special networks.
One or two relay pulse outputs transmit energy to a PLC, power management system or remote counter. The pulse rate is selectable from 1 to 4000 pulses per unit with a pulse duration of 100 ms; contacts are rated 250 V AC, 6 A. Isolation is 1000 V AC across open contacts and 4000 V AC between coil and contacts.
Three versions are available. The basic WQR96 MKII has one register and one pulse output. The WQR96-x MKII and WQR96-c MKII add an analogue instrument for simultaneous indication of momentary power, with a 90° or a 240° scale, so energy and load are visible on the same panel cut-out.
The meters are powered with 60, 100, 230 or 400 V AC auxiliary voltage and operate from −10 to 55 °C at relative humidity up to 75 %. They are tested for vibration and hold a DNV approval for marine use. The front is IP52, or IP54 with an optional gasket, and terminals are IP20.
Typical applications are generator and genset panels, power and energy management, grid connection, hybrid and microgrid systems with solar and storage, and switchboards on ships and offshore units. Please specify network type, CT ratio, auxiliary voltage and the version required.
WQR96 MKII, WQR96-x MKII, WQR96-c MKII
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.