ADL-111Q96 is an insulation monitoring instrument for DC networks operating at 24, 110 or 220 V DC. It continuously supervises the insulation resistance between an isolated voltage distribution network (IT network) and earth or a safety cable, and indicates or signals when the insulation deteriorates. The instrument is used mainly in marine, offshore and subsea installations, for example on offshore supply vessels and subsea IMR vessels, and for DC control voltages in transformer stations.
To determine the insulation resistance, the instrument applies a DC measuring voltage of alternating polarity to the network and measures the resulting current. An automatic measuring cycle compensates for network capacitances and DC components, so leakage capacitances of up to 120 µF are permitted. The measuring range is 0 to 10 MΩ with an accuracy of ±5 % of scale length, and the response time lies between 1 s and 396 s.
The set point is adjusted with a potentiometer on the rear. A change-over relay contact can be configured as normally energised (NE) for alarm purposes or normally de-energised (ND) for control purposes. Contact ratings are 8 A at 250 V AC (AC1) or 24 V DC (DC1), and 3 A at 250 V AC (AC15) or 24 V DC (DC13). LED indicators show meter, fault and supervision status. The auxiliary supply, also 24, 110 or 220 V DC, should be protected by a 2 A fuse.
The instrument is panel-mounted in a 92 × 92 mm cut-out. The front is protected to IP52, or IP54 with the optional rubber gasket; the rear and terminals are IP20. Screw terminals accept 2.5 mm² stranded or 4 mm² solid conductors. Operating temperature is −25 to 65 °C. The device is CE marked and designed to EN 61010-1, EN 61326-1 and EN 61326-2-4, with environmental tests to EN IEC 60068.
Options include anti-glare glass, IP54 front protection and an individually adjustable red pointer (IP52 only). ADL devices must not be connected in parallel, and the measuring wire must be disconnected when the network is tested with a high-voltage insulation tester.
Please state the network voltage, auxiliary voltage and the required options when you request a quotation.
2911750110-01, 2911750110-02, 2911750110-03, 2911750110-04, 2911750110-05, 2911750110-06
Match the instrument to the circuit and measurement category. Include the wiring arrangement and ratios of any external current or voltage transformers.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.